English
Language : 

R2023T-E2-F Datasheet, PDF (26/56 Pages) RICOH electronics devices division – 2-wire Serial Interface Real Time Clock IC
R2023x
* R2023K (FFP12) is the discontinued product as of February, 2016.
SCL
from the master
1
2
SDA from
the transmission side
SDA from
the receiving side
Start
Condition
8
9
Acknowledge
signal
(3) Data Transmission Format in I2C-Bus
I2C-Bus has no chip enable signal line. In place of it, each device has a 7bit Slave Address allocated. The
first 1byte is allocated to this 7bit address and to the command (R/W) for which data transmission direction is
designated by the data transmission thereafter. 7bit address is sequentially transmitted from the MSB and 2
and after bytes are read, when 8bit is “H” and when write “L”.
The Slave Address of the R2023x is specified at (0110010).
At the end of data transmission / receiving, Stop Condition is generated to complete transmission. However, if
start condition is generated without generating Stop Condition, Repeated Start Condition is met and
transmission / receiving data may be continue by setting the Slave Address again. Use this procedure when
the transmission direction needs to be change during one transmission.
Data is written to the slave
from the master
When data is read from the
slave immediately after 7bit
addressing from the master
When the transmission
direction is to be changed
during transmission.
S Slave Address 0 A
Data
A
Data
AP
(0110010)
R/W =0(W rite)
S Slave Address 1 A
Data
A
Data
/A P
(0110010)
R/W =1(Read)
Inform read has been completed by not generate
an acknowledge signal to the slave side.
S Slave Address 0 A
Data
A Sr Salve Address 1
(0110010)
R/W =0(W rite)
(0110010) R/W=1(Read)
A
Data
A
Data
/A P
Master to slave
S Start Condition
Inform read has been completed by not generate
an acknowledge signal to the slave side.
Slave to master
A A /A Acknowledge Signal
P Stop Condition
Sr Repeated Start Condition
26