RT8082
Parameter
Symbol
Test Conditions
Min Typ Max Unit
Power Good Falling Threshold
Power Good Resistance
VFB Falling (Fault), TA = 25°C -- 93 90
%
VFB Falling (Good), TA = 25°C -- 107 110
IPGOOD = 500μA
-- 145 250 Ω
Enable Threshold Voltage
EN Rising
0.5 0.85 1.3 V
Enable Voltage Hysteresis
-- 50 -- mV
Enable Input Current
-- 0.1 2 μA
Over Temperature Protection
-- 160 -- °C
Over Temperature Protection Hysteresis
-- 20 -- °C
Note 1. Stresses beyond those listed “Absolute Maximum Ratings” may cause permanent damage to the device. These are
stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated in
the operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions may
affect device reliability.
Note 2. θJA is measured at TA = 25°C on a high effective thermal conductivity four-layer test board per JEDEC 51-7. θJC is
measured at the exposed pad of the package.
Note 3. Devices are ESD sensitive. Handling precaution is recommended.
Note 4. The device is not guaranteed to function outside its operating conditions.
Copyright ©2012 Richtek Technology Corporation. All rights reserved.
DS8082-00 November 2012
is a registered trademark of Richtek Technology Corporation.
www.richtek.com