English
Language : 

DS-ELITE-1 Datasheet, PDF (6/8 Pages) rfsolutions.ltd – Whatever your switching application the ELITE Remote control system with 4 individual 230V outputs and it’s completely waterproof IP68 enclosure will be a great choice.
ELITE Remote control System
Advanced operation continued…
Installation TEST MODE
The ELITE comes with an in-built test mode which allows a user to check the signal strength of any
compatible handheld:
1. Press the SIGNAL TEST button on the PCB
2. Press any button/activate the transmitter which you want to test
3. LEDs 1-8 will show a bar graph of the signal strength - the more LEDs on the better the signal
TIP: Try the transmitter in the location where it will be used to make sure it will work once installation is com-
plete.
Note: When in test mode and paired transmitter will still activate its relay.
For reliable communications please ensure at least 3 LED’s are lit.
Installation TIMER SELECT MODE
NOTE: As default all timers are set to 0 seconds.
The ELITE has a timer option which can be set individually on each output. Meaning that you can set any out-
put to de-activate after a different amount of time should you wish
1. To enter timer select mode - Press the TIMER SELECT button
2. Select your chosen output by pressing the TIMER SELECT button to scroll through each relay in turn
3. When the LED for the required output is flashing wait until it becomes solidly LIT
4. Press the TIMER SELECT button again to increase the timer delay in line with the table belo
5. When you have selected the required delay, wait 3 seconds. All Red LEDs will flash to show that the set-
ting is saved
0 LED
0s
1 LED
½s
2 LED
5s
3 LED
10s
4 LED
30s
5 LED
1m
6 LED
10m
7 LED
30m
8 LED
1hr
Note: Settings are saved even after power is removed.
When zero LED’s are lit the relays will operate as per the jumper links. Momentary or latching.
Setting MOMENTARY / LATCHING links
NOTE: As default all relay switches are latching.
It is possible to set the relay switches on the ELITE receiver to either momentary or latching operation
(Latching - one press for on, one press for off, Momentary - On while button is held only)
1. Remove all power from the receiver and then open the ELITE-RX receiver enclosure. Unscrew the an-
tenna and slide out the PCB.
2. The Momentary/Latching Setting links are in the position shown as (C) page 4.
3. To set a relay switch to momentary, simply set the links as per the below table for the appropriate relay
switch.
4. Re-assemble the ELITE-RX and re-apply the power.
DS-ELITE-1