English
Language : 

RFSW6024 Datasheet, PDF (3/13 Pages) RF Micro Devices – 300MHz to 6000MHz Operation
RFSW6024
Parameter
Specification
Unit
Min Typ Max
Condition
General Performance -
Continued
Isolation (RF1 to RF2)
Return Loss (RF1/RF2 On-state)
Return Loss (RF1/RF2 Off-state)
Input IP3
Input 0.1dB Compression Point
Input 1dB Compression Point
Settling Time
Start-up Time
Switching Speed
Power Supply
Electrical Specifications, TA = 25°C, VCRTL = 0/+5 VDC,
VDD = +5VDC, 50Ω system.
80
dB 0.3GHz
70
dB 1GHz
60
dB 2GHz
53
dB 3GHz
48
dB 4GHz
49
dB 5GHz
28
dB 0.3GHz
27
dB 1GHz
20
dB 2GHz
20
dB 3GHz
22
dB 4GHz
17
dB 5GHz
37
dB 0.3GHz
36
dB 1GHz
30
dB 2GHz
27
dB 3GHz
23
dB 4GHz
20
dB 5GHz
65
dBm 1GHz + 12dBm input power per tone, 1MHz tone spacing
65
dBm 2GHz + 12dBm input power per tone, 1MHz tone spacing
36
dBm
1GHz
36
dBm
2
µs 50% Control to internal negative voltage at 90% final value
10
µs 90% VDD to internal negative voltage at 90% final value
250
ns 50% control to 10/90% RF
Supply Current (IDD)
Control Current (ICTL, IEN)
Low Control Voltage (VCTL)
High Control Voltage (VCTL)
140 170 µA VDD = 5.0V
0.5
5
µA VCTL = 5.0V
0
0.63 V
1.8V Logic compatible
1.1
VDD V
Notes:
1. S-parameters have the PCB de-embedded
2. RF ports need to be at 0V DC. If > 0.5V is present on RF lines, blocking caps are required.
RF Micro Devices Inc. 7628 Thorndike Road, Greensboro, NC 27409-9421
DS150202
For sales or technical support, contact RFMD at +1.336.678.5570 or customerservice@rfmd.com.
The information in this publication is believed to be accurate. However, no responsibility is assumed by RF Micro Devices, Inc. ("RFMD") for its use, nor for any infringement of patents or other rights of
third parties resulting from its use. No license is granted by implication or otherwise under any patent or patent rights of RFMD. RFMD reserves the right to change component circuitry, recommended
application circuitry and specifications at any time without prior notice.
3 of 13