English
Language : 

RFSW8006Q Datasheet, PDF (2/6 Pages) RF Micro Devices – Symmetric SP3T Switch
RFSW8006Q
Absolute Maximum Ratings
Parameter
Supply Voltage
ESD Human Body Model (HBM)
ESD Charged Device Model (CDM)
Operating Case Temperature
Storage Temperature
Moisture Sensitivity Level
Rating
5
2000
1000
-40 to +105
-40 to +150
MSL2
Unit
V
V
V
°C
°C
Caution! ESD sensitive device.
RFMD Green: RoHS status based on EU
Directive 2011/65/EU (at time of this
document revision), halogen free per IEC
61249-2-21, < 1000ppm each of antimony
trioxide in polymeric materials and red
phosphorus as a flame retardant, and
<2% antimony in solder.
Nominal Operating Parameters
Exceeding any one or a combination of the Absolute
Maximum Rating conditions may cause permanent
damage to the device. Extended application of Absolute
Maximum Rating conditions to the device may reduce
device reliability. Specified typical performance or
functional operation of the device under Absolute
Maximum Rating conditions is not implied.
Parameter
Specification
Unit
Min Typ Max
Condition
Operating Parameters
Operating Frequency Range
VDD
Switch Control Voltage: Low
Switch Control Voltage: High
RF1 – ANT
Insertion Loss
Input Return Loss
Output Return Loss
RF1 to RF2 Isolation
RF1 to RF3 Isolation
RF2 – ANT
Insertion Loss
Input Return Loss
Output Return Loss
RF2 to RF1 Isolation
RF2 to RF3 Isolation
RF3 – ANT
Insertion Loss
Input Return Loss
Output Return Loss
RF3 to RF1 Isolation
RF3 to RF2 Isolation
100
4000 MHz
2.7 3.6 4.8
V
0
0.20 V
1.2
4.8
V
VDD = 3.6V; CRF1 = 1.2V to 4.8V; T = -40°C to 105°C;
2412MHz to 2484MHz; Unless otherwise noted
0.5
dB T = 25°C
0.6 1.2 dB All conditions
20
15
dB
20
15
dB
25 30
dB Measured ANT - RF2
25 30
dB Measured ANT – RF3
VDD = 3.6V; CRF2 = 1.2V to 4.8V; T = -40°C to 85°C;
2412MHz to 2484MHz; Unless otherwise noted
0.6
dB T = 25°C
0.6 1.2 dB T = 105°C
20
15
dB
20
15
dB
23 25
dB Measured ANT - RF1
28 31
dB Measured ANT - RF3
VDD = 3.6V; CRF3 = 1.2V to 4.8V; T = -40°C to 85°C;
2412MHz to 2484MHz; Unless otherwise noted
0.6
dB T = 25°C
0.6 1.2 dB T = 105°C
20
15
dB
20
15
dB
23 26
dB Measured ANT – RF1
27 31
dB Measured ANT – RF2
RF Micro Devices Inc. 7628 Thorndike Road, Greensboro, NC 27409-9421
For sales or technical support, contact RFMD at +1.336.678.5570 or customerservice@rfmd.com.
DS150129
The information in this publication is believed to be accurate. However, no responsibility is assumed by RF Micro Devices, Inc. ("RFMD") for its use, nor for any infringement of patents or other rights of
third parties resulting from its use. No license is granted by implication or otherwise under any patent or patent rights of RFMD. RFMD reserves the right to change component circuitry, recommended
application circuitry and specifications at any time without prior notice.
2 of 6