1. This product is designed to be used for broadband
amplification. Heat generation is higher when there is no RF
signal in the device. Therefore, the worst case scenario is
when there is no RF signal, and the amplifier is “on” with
current draw.
The temperature must be calculated properly.
Case temperature must maintain below 80°C.
Right side drawing notes how to use a temperature
monitoring function to protect against overheating.
2. Thermal Grease or Metal Thermal Interface Materials are
recommended for heat dissipation. An example would be
spreading
thermal grease on the bottom of the device
RF IN
Vcc(+28V)
Shut Down
(+5V)
RF OUT
Temp Monitor
Switch ON/OFF
+Vcc
+
-
Ref Voltage
Korean Facilities : 82-31-250-5078 / rfsales@rfhic.com
US Facility : 919-677-8780 / sales@rfhicusa.com
Comparator Block (with hysteresis gap)
All specifications may change without notice