Precautions
1. This product is designed to be used for broadband amplification.
Heat generation is higher when there is no RF signal in the
device. Therefore, the worst case scenario is when there is
no RF signal, and the amplifier is “on” with current draw.
The temperature must be calculated properly.
Case temperature must maintain below 85°C.
Right side drawing notes how to use a temperature monitoring
function to protect against overheating.
2. Thermal Grease or Metal Thermal Interface Materials are
recommended for heat dissipation. An example would be spreading
thermal grease on the bottom of the device.
▪ Tel : 82-31-250-5078
▪ www.rfhic.com/contact
RF IN
Vcc(+28V)
Shut Down
(+5V)
RF OUT
Temp Monitor
Switch ON/OFF
+Vcc
+
-
Ref Voltage
Comparator Block (with hysteresis gap)