English
Language : 

RWP03040-10_17 Datasheet, PDF (3/6 Pages) RFHIC – Wideband Power Amplifier
Wideband Power Amplifier
RWP03040-10
Typical Performance @ 25°C
Frequency
(MHz)
20
100
200
300
400
520
P1dB
(dBm)
45.5
46.2
46.6
45.8
46.8
46.1
P3dB
(dBm)
46.0
47.0
47.3
46.9
47.9
47.7
Current @P1dB
(A)
2.7
2.9
3.5
3.4
3.5
3.5
Current @P3dB
(A)
2.68
3.00
3.77
3.80
3.85
4.03
2nd Harm @30dBm OIP3 (30dBm/Tone)
(dBc)
(dBm)
-57.51
55.7
-49.11
56.9
-48.43
56.3
-52.39
54.8
-71.33
54.8
-57.16
55.0
Pout & Ids @ P3dB VS Frequency
53
7.5
53
52
7
52
51
6.5
51
50
6
50
49
5.5
49
Pout
48
5
48
47
4.5
IDS
47
46
4
46
45
3.5
45
44
3
44
43
2.5
43
Frequency[MHz]
Precaution
1. This product is designed to be used for broadband amplification. Heat
generation is higher when there is no RF signal in the device.
Therefore, the worst case scenario is when there is no RF signal, and
the amplifier is “on” with current draw.
The temperature must be calculated properly.
Case temperature must maintain below 80°C.
Right side drawing notes how to use a temperature monitoring function
to protect against overheating.
2. Thermal Grease or Metal Thermal Interface Materials are
recommended for heat dissipation. An example would be spreading
thermal grease on the bottom of the device
PouPtou@t @P3Pd3BdBVVSSFTreemqpuency
TC=-10˚C
TC=45˚C
TC=80˚C
Frequency[MHz]
RF IN
Vcc(+28V)
Shut Down
(+5V)
RF OUT
Temp Monitor
Switch ON/OFF
+Vcc
+
-
Ref Voltage
Comparator Block (with hysteresis gap)
Korean Facilities : 82-31-8069-3036 / rfsales@rfhic.com
US Facility : 919-677-8780 / sales@rfhicusa.com
3/6