English
Language : 

RWM03060-10 Datasheet, PDF (2/8 Pages) RFHIC – Wideband Power Amplifier
Wideband Power Amplifier RWM03060-10
Alarm Functions
DESCRIPTION
Over Current Protection
Over Heat Protection
SPECIFICATIONS
Shutdown : 10A±1A
Recovery time : after 60sec or DC power off and on
Shutdown : over 85℃
Recovery : under 60℃
Over Input Power Protection RF input level : 3dBm ±2dB
HPA STATUS
Amplifier shutdown
(current consumption : 380mA @
amplifier shutdown)
No shutdown, just gain is only reduced.
(amplifier gain : -35~ -40dB)
Environmental Characteristics
PARAMETER
Operating Case Temperature
Storage Temperature
UNIT
°C
°C
MIN
-30
-45
Relative humidity w/o
%
-
condensation
Altitude
Feet
10,000
Shock & Vibration
-
Note
When case temperature limits over 85C, module will be shutdown.
TYP
-
-
-
30,000
Per Mil Std 810E
MAX
85
105
95
-
SYMBOL
Tc
Tstg
RH
ALT
SH / VI
Mechanical Specifications
PARAMETER
Dimensions
Weight
RF Connectors In/Out
DC & Control Signals
Connector
Cooling
UNIT
Inch
mm
lb.
Kg
-
-
-
VALUE
6.4 x 3.4 x 1.1
162.6 x 86.4 x 27.0
1.3
0.63
SMA female
D-sub, 9-Pin
External Heat-sink
LIMIT
-
-
-
-
-
Korean Facilities : 82-31-250-5078 / rfsales@rfhic.com
US Facility : 919-677-8780 / sales@rfhicusa.com
2/8
All specifications may change without notice