English
Language : 

M66290AGP Datasheet, PDF (14/54 Pages) Mitsubishi Electric Semiconductor – USB DEVICE CONTROLLER
MITSUBISHI <DIGITAL ASSP>
M66290AGP/FP
USB DEVICE CONTROLLER
(2-1) Interrupt Enable Register 0 (Address : 10h)
D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0
VBSE RSME SOFE DVSE CTRE BEMPE INTNE INTRE URST SADR SCFG SUSP WDST RDST CMPL SERR
Bit
Bit
Name
Name
15 VBSE
Vbus interrupt
enable
0 : Disable
1 : Enable
Resume interrupt 0 : Disable
14 RSME
enable
1 : Enable
13 SOFE
SOF interrupt
enable
0 : Disable
1 : Enable
12 DVSE
Device state 0 : Disable
interrupt enable 1 : Enable
Control transfer 0 : Disable
11 CTRE
interrupt enable 1 : Enable
Endpoint5-0 buffer
10 BEMPE empty/size error 0 : Disable
1 : Enable
interrupt enable
Endpoint5-0 buffer
0 : Disable
9 INTNE
not ready
interrupt enable 1 : Enable
Endpoint5-0 buffer
0 : Disable
8 INTRE
ready
1 : Enable
interrupt enable
Function
Reset
W/R
H/W S/W USB
W/R 0 0 -
W/R 0 0 -
W/R 0 0 -
W/R 0 0 -
W/R 0 0 -
W/R 0 0 -
W/R 0 0 -
W/R 0 0 -
7 URST USB reset detect If this bit is "1", then the DVST flag is set when detected USB reset.
W/R 0 0 -
6 SADR
Set Address
execute
If this bit is "1", then the DVST flag is set after executed SetAddress.
W/R 0 0 -
Set Configration
5 SCFG
execute
If this bit is "1", then the DVST flag is set after executed SetConfigration. W/R 0 0 -
4 SUSP
Suspend
detect
If this bit is "1", then the DVST flag is set when detected suspend.
W/R 0 0 -
Control write
If this bit is "1", then the CTRT flag is set when shifted to status stage
3 WDST transfer status
stag e
in control write transfer.
W/R 0 0 -
Control read
If this bit is "1", then the CTRT flag is set when shifted to status stage
2 RDST transfer status
stag e
in control read transfer.
W/R 0 0 -
Control transfer If this bit is "1", then the CTRT flag is set when control transfer
1 CMPL
complete
completed (when the status stage completed normally).
W/R 0 0 -
Control transfer If this bit is "1" then the CTRT flag is set when error
0 SERR
sequence error occurred in the sequence of control transfer.
W/R 0 0 -