RXXPXX-R Datasheet, PDF (3/3 Pages) Recom International Power – EN-60601 for Medical Applications
ECONOLINE
DC/DC-Converter
EMC Filter Suggestions for EN55022 Class A and B
EN55022 Class A
RxxPxxS_D
/Rx Series
+
Input C1
Output
C1
RxxPxx/R6.4 10μF
RxxPxx/R8 10μF
C2
2n2F 8kV
Vishay HGZ222MBP
2n5F 10kV
Vishay HGZ222MBP
C2
EN55022 Class B
L1
+
+
Input C1
C2
Output
C1
L1
C2
C3
RxxPxx/R6.4 10μF
470μH
WE 7447471471
10μF
2n2F 8kV
Vishay HGZ222MBP
RxxPxx/R8
10μF
470μH
WE 7447471471
10μF
2n5F 10kV
Vishay HGZ222MBP
C3
Package Style and Pinning (mm)
7 PIN SIP Package
RECOM
R05P05D/R6.4 or
12.5
5
R05P05D/R8
tc ****
0.5
5
9.8
Dual Output
Single Output
Single Output
RECOM
RxxPxxD/R6.4
****
RECOM
RxxPxxS/R8
****
RECOM
RxxPxxS/X2/R6.4
****
4.1
7.62
0.5
pin clearance
19.5
Bottom View
0.25
2.4
1.9
15.24
19.5
/X2 Bottom View 0.25
2.4
1.9
10.16
pin clearance
12
5 67
12
57
12
67
Recommended Footprint Details
1.00ø+0.15/–0
2.54
2.54
2.54
Top View
1.00ø+0.15/–0
Pin Connections
Pin # Single
1
+Vin
2
-Vin
5
–Vout
6
No Pin
7
+Vout
Dual
+Vin
–Vin
–Vout
Com
+Vout
XX.X ± 0.5 mm
XX.XX ± 0.25 mm
/X2
+Vin
–Vin
No Pin
–Vout
+Vout
2.54
/X2 Top View