English
Language : 

RXXPXX-R Datasheet, PDF (1/3 Pages) Recom International Power – EN-60601 for Medical Applications
Features
Unregulated
Converters
● UL/CSA and EN Safety certified
● EN-61010 for Test, Measurement and Lab Use
● EN-60601 for Medical Applications
● Reinforced Isolation 6.4kVDC or 8kVDC
● Optional Continuous Short Circuit Protected
● Unique Reinforced Isolation Transformer System
● /X2 Option for >9mm Input/Output Clearance
ECONOLINE
DC/DC-Converter
with 3 year Warranty
Description
The RxxPxxS_D Series of DC/DC Converters are certified to UL/CSA-60950. This makes
them ideal for safety applications where approved or reinforced isolation is required. The
reinforced versions are also EN61010-1 certified for Lab Equipment Safety.
Selection Guide
Part
Number
SIP 7
Reinforced
Isolation
(kVDC)
Input
Voltage
(VDC)
Output
Voltage
(VDC)
Output
Current
(mA)
Efficiency
Std
(%)
Max
Capacitive
Load(1)
RxxP3.3S* /R6.4 & /R8 5, 9, 12, 15, 24 3.3
303
70~80 2200µF
RxxP05S* /R6.4 & /R8 5, 9, 12, 15, 24 5
200
75-80
1000µF
RxxP09S* /R6.4 & /R8 5, 9, 12, 15, 24 9
111
75-82
1000µF
RxxP12S* /R6.4 & /R8 5, 9, 12, 15, 24 12
84
75-82
470µF
RxxP15S* /R6.4 & /R8 5, 9, 12, 15, 24 15
66
75-83
470µF
RxxP3.3D* /R6.4 & /R8 5, 9, 12, 15, 24 ±3.3
±151
72-79 ±1000µF
RxxP05D* /R6.4 & /R8 5, 9, 12, 15, 24 ±5
±100
75-82
±470µF
RxxP09D* /R6.4 & /R8 5, 9, 12, 15, 24 ±9
±55
75-82
±470µF
RxxP12D* /R6.4 & /R8 5, 9, 12, 15, 24 ±12
±41
75-82
±220µF
RxxP15D* /R6.4 & /R8 5, 9, 12, 15, 24 ±15
±33
75-83
±220µF
xx = Input Voltage. Other input and output voltage combinations available on request.
* add Suffix “P” for Continuous Short Circuit Protection, e.g. R05P05S/P, R05P05D/P
* add Suffix “/X2” for single output with alternative pinout, e.g. R05P05S/X2, R05P05S/P/X2
* add Suffix “/R6.4” or “/R8” for Reinforced Isolation, e.g. R05P05D/R6.4, R05P05S/P/X2/R8
Specifications (measured at TA = 25°C, nominal input voltage, full load and after warm-up)
Input Voltage Range
±10%
Output Voltage Accuracy
±5%
Line Voltage Regulation
1.2%/1% of Vin typ.
Load Voltage Regulation
3.3, 5V output types
15% max.
(10% to 100% full load)
other output types
10% max.
Output Ripple and Noise (20MHz BW)
200mVp-p max.
Operating Frequency
20kHz min. / 50kHz typ. / 85kHz max.
Efficiency at Full Load
65% min. / 75% typ.
Minimum Load = 0%
Specifications valid for 10% minimum load only.
Reinforced Isolation /R6.4
(tested for 1 second)
6400VDC
(rated for 1 minute**)
3200VAC / 60Hz
Reinforced Isolation /R8
(tested for 1 second)
8000VDC
(rated for 1 minute**)
4000VAC / 60Hz
Isolation Capacitance
4pF min. / 10pF max.
Isolation Resistance
15 GΩ min.
Short Circuit Protection
1 Second
P-Suffix
Continuous
Operating Temperature Range (free air convection)
-40°C to +85°C (see Graph)
Case Temperature
105°C max.
Storage Temperature Range
-55°C to +125°C
Relative Humidity
95% RH
Package Weight
4.3g
Packing Quantity
25 pcs per Tube
Potting Material
Silicone Rubber Compound (UL94V-0)
continued on next page
1 Watt
SIP 7 Single
& Dual Output
RoHS
2011/65/EU
6/6
E314885
EN-60950-1 Certified
EN-60601-1 Certified
UL/CSA 60950-1 Certified
UL-60601-1 Certified
EN-61010-1 Certified
IEC-60601-1 CB Report
RxxPxx/R
Derating-Graph
(Ambient Temperature)
100
80
60 Safe Operating Area
40
20
0
-40
0
50
100 150
85
Operating Temperature °C
**Any data referred to in this datasheet are of indicative
nature and based on our practical experience only. For
further details, please refer to our Application Notes.
Refer to Application Notes
www.recom-power.com
REV: 2/2015
E-73