English
Language : 

RXXP2XX-R Datasheet, PDF (2/4 Pages) Recom International Power – EN-61010 for Test, Measurement and Lab Use
ECONOLINE
DC/DC-Converter
RxxP2xxS_D
/Rx Series
Specifications (measured at TA = 25°C, nominal input voltage, full load and after warm-up)
Operating Temperature Range (free air convection)
-40°C to +85°C (see Graph)
Storage Temperature Range
-55°C to +125°C
Relative Humidity
95% RH
Package Weight
4.3g
Packing Quantity
25 pcs per Tube
Potting Material
} MTBF (+25°C)
. (+85°C)
Detailed Information see
Application Notes chapter "MTBF"
Reinforced
Reinforced Isolation
Transformer Creepage
Transformer Clearance
PCB Creepage & Clearance
Certifications
Measurement, Control and Laboratory Use Safety
CSA General Safety
UL/cUL Medical Safety
CSA Medical Safety
EN General Safety
CB/EN Medical Safety
ANSI/AAMI Medical Safety
Reinforced Types
Reinforced Types
Reinforced Types
Silicone Rubber Compound (UL94V-0)
1154 x 103 hours
168 x 103 hours
5.5 mm min.
5.5 mm min.
4.6 mm min.
Report: T1301251-313
Report: 2207629
Report: 314885-A5
Report: 2207629
Report: SPCLVD1310079-1
Report: CA-10169-A1-UL
Report: E314885-A5
EN 61010-1 : 2010
UL 60950-1 1st Edition
C22.2 No. 60950-1-03
UL60601-1 1st Edition
CAN/CSA-22.2 No 601.1-M90
EN60950-1 : 2006
IEC/EN 60601-1 3rd Edition
ES60601-1 3rd Edition
Notes
Note 1
Maximum capacitive load is defined as the capacitive load that will allow start up in under 1 second without damage to the converter.
Tolerance Envelope
+10%
+5%
V Nom.
Typical Load Line
+5%
– 1.5%
– 5%
Typical Characteristics
10%
50%
100%
Output Load Current (%)
RxxP205S/R6.4 and RxxP205S/R8
Efficiency / Load
100
R12P205S/R6.4
80
R05P205S/R6.4
60
R24P205S/R6.4
40
20
0
0% 20% 40% 60%
Total Output current (%)
80% 100%
Deviation / Load
25.000
20.000
15.000
10.000
R12P205S/R6.4
R24P205S/R6.4
5.000
0.000
-5.000
-10.000
R05P205S/R6.4
0% 20% 40% 60% 80%
Total Output current (%)
100%
www.recom-power.com
REV: 2/2015
E-101