English
Language : 

R1S-0505 Datasheet, PDF (2/4 Pages) Recom International Power – 1 Watt SMD Single & Dual Output
ECONOLINE
DC/DC-Converter
Specifications - continued
Isolation Voltage
(tested for 1 second)
1000VDC
(rated for 1 minute)
500VAC / 60Hz
Isolation Voltage
H-Suffix
(tested for 1 second)
3000VDC
H-Suffix
(rated for 1 minute)
1500VAC / 60Hz
Isolation Capacitance
R1S, R1S8, R1D, R1D10
15pF min. / 70pF max.
R1S12, R1D12
10pF min. / 75pF max.
Isolation Resistance
10 GΩ min.
Short Circuit Protection
1 Second
P-Suffix
Continuous
Operating Temperature Range (free air convection)
-40°C to +100°C (see Graph)
Storage Temperature Range
-55°C to +125°C
Reflow Temperature
ROHS compliant
245°C (30 sec), Peak 255°C (5 sec) max.
Vapour Phase Process
(for more details see Application Notes)
230°C (90 sec) max.
Relative Humidity
95% RH
Humidity Susceptibility Test
1000 hrs / 90% humidity / +85°C ambient
Package weight
R1S
1.0g
R1S8
1.1g
R1S12, R1D, R1D10, R1D12
1.2g
Packing Quantity
R1S, R1S8
40 pcs per Tube
R1S12, R1D, R1D10, R1D12
33 pcs per tube
All Types
500 pcs per Reel
} MTBF (+25°C) Detailed Information see
using MIL-HDBK 217F
(+85°C) Application Notes chapter "MTBF" using MIL-HDBK 217F
4275 x 103 hours
1365 x 103 hours
CERTIFICATIONS
CB Test Report
Report: US/14402A/UL
IEC 60950-1:2001 1st Ed.
UL General Safety Report: E358085
UL 60950-1 2nd Ed.
CUL General Safety
C22.2 No. 60950-1-03
EN Medical Safety Report: MDD1205098-2 + RM1205098-2
IEC/EN 60601-1 3rd Edition
Medical Report + ISO14971 Risk Assessment
EN General Safety Report: SPCLVD1211033-3
EN60950-1: 2006 + A12:2011
Conducted / Radiated Emissions
EN55022
Level A
Notes
Note 1: Maximum capacitive load is defined as the capacitive load that will allow start up in under
.
1 second without damage to the converter.
Typical Characteristics
R1S**-xx05
Tolerance Envelope
+10%
+5%
Typical Load Line
+5%
V Nom.
– 1%
– 5%
Efficiency / Load
100
3.305
1205
80
60
0505
40
20
0
0% 20% 40% 60%
Total Output current (%)
80% 100%
10%
50%
100%
Output Load Current (%)
www.recom-international.com
Deviation / Load
25.000
20.000
15.000
10.000
3.305
0505
5.000
0.000
-5.000
1205
-10.000
0% 20% 40% 60% 80%
Total Output current (%)
100%
REV: 1/2013
R1S_R1D
Series
Derating-Graphs
(Ambient Temperature)
R1S-0505, R1D-0505
100
80
60 Safe Operating Area
40
20
0
-40
0
50
100
150
Operating Temperature °C 105
The derating graphs are valid
only for the part numbers shown.
R1D**-xx05
Efficiency / Load
100
0505
1205
80
60
40
3.305
20
0
0% 20% 40% 60%
Total Output current (%)
80% 100%
Deviation / Load
25.000
20.000
15.000
3.305
0505
10.000
5.000
0.000
-5.000
1205
-10.000
0% 20% 40% 60% 80%
Total Output current (%)
100%
E-25