English
Language : 

U6264A Datasheet, PDF (6/9 Pages) –
U6264A
Test Configuration for Functional Check
5V
A0
VCC
A1
A2
VIH
VIL
A3
A4
A5
A6
A7
A8
A9
A10
A11
DQ0
DQ1
DQ2
DQ3
DQ4
DQ5
DQ6
DQ7
A12
960
VO
E1
E2
W
G
VSS
30 pF1)
510
1) In measurement of tdis(E), tdis(W), tdis(G) the capacitance is 5 pF.
Capacitance
Conditions
Symbol
Input Capacitance
Output Capacitance
VCC = 5.0 V
VI = VSS
CI
f = 1 MHz
Ta = 25 °C
CO
All pins not under test must be connected with ground by capacitors.
Min.
Max.
Unit
8
pF
10
pF
IC Code Numbers
Example
U6264A
Type
Package
D = PDIP
S = SOP (330 mil)
S1 = SOP (300 mil)
Operating Temperature Range
C = 0 to 70 °C
G = -25 to 85 °C
K = -40 to 85 °C
D G 07 L
Access Time
07 = 70 ns
10 = 100 ns
Internal Code
Power Consumption
= Standard
L = Low Power
LL = Very Low Power
The date of manufacture is given by the last 4 digits of the mark, the first 2 digits indicating the year, and the last 2
digits the calendar week.
6