14. REPLACING UNITS WHILE THE SYSTEM IS RUNNING
This feature is available only for the CP20.241-R2 unit, which is equipped with hot-swappable plug connectors.
Fig. 14-1 Replacing the power supply or redundancy module while the system is running
Load
3a
3b
+-
Output 24V 20A
DC-OK
DC-
OK
CP20.241-R2
Power Supply
Input
L N PE
+-
Output 24V 20A
DC-OK
DC-
OK
CP20.241-R2
Power Supply
Input
L N PE
2a
1a I
L
N
PE
2b
1b I
Replacement instructions (Example for left power supply):
- Switch-off circuit breaker (1a).
- Remove plug (2a).
- Remove plug (3a). The plug prevents the cables from shorting.
- Change power supply.
- Put the plug (3a) back in.
- Put the plug (2a) back in.
- Turn-on the circuit breaker (1a).
- The circuit is redundant again.
To replace the right power supply, repeat the process above using (1b), (2b) and (3b).