English
Language : 

MLY10.241 Datasheet, PDF (11/16 Pages) PULS GmbH – DC12-48V (120V), 10A, DUAL REDUNDANCY MODULE
MiniLine-2
MLY-Series
MLY10.241
DC12-48V (120V), 10A, DUAL REDUNDANCY MODULE
11. PROTECTION FEATURES
Output over-current protection
Reverse input polarity protection
Degree of protection
Penetration protection
Over-temperature protection
Input transient protection
Output transient protection
Internal input fuse
not included
included
IP 20
> 2.5mm
not included
not included
not included
not included
unit does not start when input voltage is reversed
EN/IEC 60529
e.g. screws, small parts
12. SAFETY FEATURES
Input / output separation
Safety level of output voltage
Class of protection
no galvanic separation
200V epitaxial diode between input and output
The output voltage is regarded to be SELV (EN 60950-1) or PELV (EN 60204-1, EN
50178, IEC 60364-4-41) if the input voltage fulfills the requirements for a SELV
source or PELV source.
III
plastic housing, PE connection not required
Apr. 2014 / Rev. 1.5 DS-MLY10.241-EN
All parameters are specified at 24V, 10A output current, 25°C ambient and after a 5 minutes run-in time unless otherwise noted
www.pulspower.com Phone +49 89 9278 0 Germany
11/16