Safety & Installa�on
Cleaning Agents and Process
These converters are components, intended exclusively for integra�on The converters are not herme�cally sealed. In order to avoid possible
into other equipment by an industrial assembly process or by a profes- damage, any penetra�on of liquids shall be avoided.
sionally competent person. Installa�on must strictly follow the safety
regula�ons in respect of the enclosure, moun�ng, creepage and clea-
rance distances, markings of the end-use applica�on.
Connec�on to the system shall be made via the female connector Po-
sitronic.
Pin 45 (Earth) is a leading pin and is connected to the case. For safety
reasons it is essen�al to connect this pin to the protec�ve earth of the
supply system.
The AC/L is internally fused. This fuse is designed to protect the con-
Isola�on
verter against overcurrent caused by a failure, but may not be able to
sa�sfy all requirements. External fuses in the wiring circuit to one or The electric strength test is performed in the factory in accordance with
both input pins (46 or 47) may be necessary to ensure compliance with IEC/EN 60950.
local requirements.
Do not open the converters, or the warranty will be invalidated. Make
sure that there is sufficient airflow available for convec�on cooling. This
should be verified by measuring the case of temperature at the speci-
fied measuring point, when the converter is operated in the end-use
Standards and Approvals
The converters are built to meet the safety standards IEC 60950-1, EN
60950-1.
‘Built to meet’ men�onned in the different paragraphs of the datasheet
means that Power System Technology has designed the product to
meet the standard but not cer�fied it in a laboratory.
‘Qualified’ means that the test has been made in a cer�fied laboratory.
Electric Strength
Characteristic
Input to Earth
Electric
Design strength
strength
Factory test for production
units (>10s)
Insulation resistance
1500
2000
Note : If Y op�on is choosen, do not apply dielectric test.
Input to
Output
3000
2000
Temperatures
Output to
Earth
500
500
> 100
Output to
Output
>100
Unit
Vrms
Vdc
Mohms
ഀऀЀԀ଀Ȁ଀ऀЀ฀
ĀȀ̀ЀԀ܀؀
ḀᔀԀ܀ᬀЀ؀ἀ
ᄀ܀ሀጀԀ᐀ᔀ
ĀȀ̀ЀԀ̀؀Ԁ܀
਀ऀ܀ࠀȀ଀ऀЀ
ༀ଀Ѐက ࠀሀ਀က ༀ̀ᄀက ༀ଀Ѐက ࠀሀ਀က ༀ̀ᄀက
ఀЀ଀Ȁ
ࠀऀ਀
ᜀ᠀ᔀጀԀ܀Ѐ؀᐀ᤀᨀᬀᔀᔀᤀᰀᔀጀԀ܀Ѐ؀᐀ᴀ
ࠀऀ਀
଀ఀഀ ࠀ฀਀
଀ഀ਀਀ ࠀ฀਀
଀ఀഀ
଀ഀ਀਀
ༀက
ሀ܀ᤀሀ᠀ᔀጀԀ܀Ѐ؀᐀
ࠀ฀਀
଀ഀऀᘀ ࠀ฀਀
଀ഀऀᘀ
Reliability
MIL-HDBK-217F, notice 2
MTBF ( Hours)
Model
CPCIAC
Heatsink Temp.
40°C
70°C
100°C
GB
285000
139500
86600
GF
165000
82300
51000
CPCI AC Rev. 00
Page 8 of 9
www.powersystemtechnology.com