English
Language : 

CPCIAC Datasheet, PDF (5/9 Pages) Power System Technology – Standard product AC-DC CompactPCI® 300W
Electromagne�c
Electromagne�c Immunity
Standard
Level Value Waveform Source imped. Test procedure Mode Criteria
DM
1KV 1,2 / 50 µs 12 ohms
OP B
Surges
Qualified EN 61000-4-5 CM 3 2KV 1,2 / 50 µs 12 ohms
OP B
CM
2KV 1,2 / 50 µs 12 ohms
Y option
OP A
Electrostatic discharge
(to case)
Qualified EN 6100-4-2
4 8000V 1 / 50µs 330 Ohms 10 pos., 10neg. OP B
Electrical fast
transients/burst
Qualified EN 61000-4-4
4 4000V 5 / 50µs
50 ohms
OP B
Note : Qualified for EN 61000-4 -2, -3, -4, -5, -6, -11, EN 61000-3-2, EN 61000-3-3
Electromagne�c Emissions
Level according to EN55022A
MIL-STD461E CE102 M op�on
Immunity to Environmental Condi�ons
Test method
Standard
Test conditions
Damp
Heat
MIL STD 810F Proc. 507-2 Humidity 93 %, 40°C, 56 days
Shock
Vibrations
20g / 18ms half size
MIL STD 810F Proc.516.3
5g / 30ms
MIL STD 810F Proc. 514-5 4-80Hz (2,8m/s²)²/Hz, non operating
160-500Hz (0,175m/s²)²/Hz, non operating
MIL STD 167A-1A
Non operating
CPCI AC Rev. 00
Page 5 of 9
Status
Conformal coating option
only (V), qualified
Qualified
Qualified
Qualified
www.powersystemtechnology.com