12 Conducted EMI Measurements
12.1 Conducted EMI Test Set-up
Conducted EMI were measured with the LED Board inside the PAR38 housing + LED
loads (12 LED ~ 36 V at 330 mA). A top cover which is isolated from the PAR38 is also
used and this cover is grounded to earth as shown on the Figure below.
Figure 74 – Conducted EMI Measurement Set-up.