LNK405EG Datasheet, PDF (1/54 Pages) Power Integrations, Inc. – 12 W Non-Isolated, Buck Topology, Power Factor Corrected, LED Driver Using LinkSwitch®-PH LNK405EG | |||
|
Design Example Report
Title
Specification
Application
Author
Document
Number
Date
Revision
12 W Non-Isolated, Buck Topology, Power
Factor Corrected, LED Driver Using
LinkSwitch®-PH LNK405EG
90 VAC â 265 VAC Input
36 VTYP, 0.33 ATYP Output
LED Driver
Applications Engineering Department
DER-192
June 9, 2010
1.0
Summary and Features
ï· Dramatically simplifies off-line, power factor corrected, LED driver design
ï· Single-stage, power factor corrected, low component count, non-isolated LED driver
ï· Configurable for TRIAC dimming or non-dimming configurations
ï· PF >0.9 across line & load (non-dimming configuration)
ï· Eliminates all control loop compensation
ï· No output current sensing required
ï· High system efficiency both at 115 V and 230 V (>83% non-dimming configuration)
ï· Advanced performance features
ï· Compensates for inductance tolerance
ï· Compensates for input voltage variations
ï· Compensates for output voltage variations
ï· Frequency jittering greatly reduces EMI filter costs
ï· Advanced protection and safety features
ï· Auto-restart protection for short-circuit
ï· Hysteretic thermal shutdown
Power Integrations
5245 Hellyer Avenue, San Jose, CA 95138 USA.
Tel: +1 408 414 9200 Fax: +1 408 414 9201
www.powerint.com
|
▷ |