EPR-31 â Multi Output, 180 W, PC Main Power Supply
12.2 Measurement Results
01-Feb-05
Figure 33 â +12 V Output Ripple,
Load: +12 V / 8 A, +5 V / 8 A, +3.3 V /
8 A, +5 V Standby / 1.5 A, â12 V /
0.2 A (2 µs and 20 mV / division).
Figure 34 â +5 V Output Ripple,
Load: +12 V / 8 A, +5 V / 8 A, +3.3 V /
8 A, +5 V Standby / 1.5 A, â12 V /
0.2 A (2 µs and 20 mV / division).
Figure 35 â +3.3 V Output Ripple,
Load: +12 V / 8 A, +5 V / 8 A, +3.3 V /
8 A, +5 V Standby / 1.5 A, â12 V /
0.2 A (5 µs and 50 mV / division).
Figure 36 â +5 V Standby Output Ripple,
Load: +12 V / 8 A, +5 V / 8 A, +3.3 V /
8 A, +5 V Standby / 1.5 A, â12 V /
0.2 A (200 µs and 50 mV / division).
Figure 37 â â12 V Output Ripple,
Load: +12 V / 8 A, +5 V / 8 A, +3.3 V /
8 A, +5 V Standby / 1.5 A, -12 V /
0.2 A (2 µs and 50 mV / division).
Power Integrations
Tel: +1 408 414 9200 Fax: +1 408 414 9201
www.powerint.com