English
Language : 

EPR-9 Datasheet, PDF (28/32 Pages) Power Integrations, Inc. – Engineering Prototype Report 5 W, Universal Input, Dual Output, Isolated, TNY266 (EP9)
5 W Universal Input Dual Output Isolated TNY266
03-April-2001
Transformer Construction
Parameters
Core/Bobbin
EE16
Core Manuf.
Generic
Bobbin Manuf.
LPmin
uHenries
Generic
954
NP
76
AWG
AWG
30
CMA
Cmils/A
722
VOR
BW
M
L
AE
ALG
BM
BAC
LG
LL
Volts
mm
mm
cm^2
nH/T^2
Gauss
Gauss
mm
uH
60.00
8.50
0.0
3.0
0.19
164
2553
924
0.13
19.1
Core and Bobbin Type
Core Manufacturing
Bobbin Manufacturing
Minimum Primary Inductance
Primary Winding Number of Turns
Primary Wire Gauge (Rounded to next smaller
standard AWG value)
Primary Winding Current Capacity (200 < CMA <
500). Warning! Primary circular mils per amp (CMA)
is too high. Decrease transformer size, decrease L,
increase NS, decrease VACmin, increase VOR,
increase KrpKdp.
Reflected Output Voltage
Bobbin Physical Winding Width
Safety Margin Width
Number of Primary Layers
Core Effective Cross Section Area
Gapped Core Effective Inductance
Maximum Operating Flux Density
AC Flux Density
Gap Length (Lg > 0.051 for TOP22X, Lg > 0.1 for
TOP23X)
Estimated Transformer Primary Leakage Inductance
LSEC
nH
20
Estimated Secondary Trace Inductance
Secondary
Parameters
NSx
Rounded Down
NSx
Rounded Down Volts
Vox
Rounded Up
NSx
Rounded Up Volts
Vox
AWGSx Range AWG
7.00 31.82 Secondary Number of Turns
31 Rounded to Integer Secondary Number of Turns
23.36 Auxiliary Output Voltage for Rounded to Integer NSx
32 Rounded to Next Integer Secondary Number of Turns
24 - 28
24.14 Auxiliary Output Voltage for Rounded to Next Integer
NSx
31 - 35
Secondary Wire Gauge Range (CMA range 500 - 200).
Wire gauge (AWG) is less than 26 AWG. Consider
parallel winding (see AN-18, AN-22).
Power Integrations, Inc.
Tel: +1 408 414 9200 Fax: +1 408 414 9201
www.powerint.com