8.6 Conducted EMI Scans
The attached plots show worst-case EMI performance for EP8 as compared to CISPR22B conducted
emissions limits. Peak detection is commonly used for initial diagnosis of EMI, as full frequency range
results can be quickly obtained, using a common spectrum analyzer. This is also a worst-case form of
analysis, as the CISPR22B limits are based on quasi-peak and average detection, both of which give lower
amplitude results than peak detection.
For EMI and safety techniques refer to PI application note AN15 (Figure 6 shows a typical test set up).
Quasi-peak
Average
Figure 8.6.1 - EP9, TNY266, L, N, 120 VAC, Full Load, CISPR Limits.
Figure 8.6.2 - EP9, TNY266, L, N, 230 VAC, Full Load, CISPR Limits.
Power Integrations, Inc.
Tel: +1 408 414 9200 Fax: +1 408 414 9201
www.powerint.com