English
Language : 

EPR-000014 Datasheet, PDF (25/28 Pages) Power Integrations, Inc. – Engineering Prototype Report - 3 W Universal Input TinySwitch-II TNY264 Power Supply
22-Feb-2002
EPR-000014 – 9 V, 0.33 A, 3 W TNY264 Adapter
10.2 Common Mode Surge Test Results
The results for common mode surge immunity testing are shown below (IEC 1000-4-5,
1.2/50 µs - 8/20 µs, L/N-G). For common mode tests, a three-wire AC cord was utilized.
AC Ground (PE) was tied from AC outlet to power supply output RTN through a copper
strap. There was a 2 Ω generator source impedance.
Compliance beyond Class 3 (2 kV), with no degradation, was confirmed.
Iteration
Voltage (VAC)
+500
-500
+1000
-1000
+1500
-1500
+2000
+2000
+3000
-3000
1
115/230
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
2
115/230
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
3
115/230
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
4
115/230
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
5
115/230
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
Table 4. Common Mode Surge Testing Results
Y-capacitor verified prior to proceeding with immunity testing.
Test
Sequence
1
2
3
4
5
6
7
8
9
10
10.3 Differential Mode 100 kHz Ring Wave Test Results
The results for differential mode 100 kHz Ring Wave immunity testing are shown below
(IEEE C62.41, L-N). For differential mode tests, a two-wire AC cord was utilized. AC
Ground (PE) was disconnected. There was a 12 Ω generator source impedance.
Compliance to 3 kV, with no degradation, was confirmed.
Iteration
Voltage (VAC)
+500
-500
+1000
-1000
+1500
-1500
+2000
+2000
+3000
-3000
1
115/230
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
2
115/230
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
3
115/230
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
4
115/230
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
5
115/230
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
Pass/Pass
Table 5. Differential Mode 100 kHz Ring Wave Test Results
Test
Sequence
1
2
3
4
5
6
7
8
9
10
Page 25 of 28
Power Integrations, Inc.
Tel: +1 408 414 9200 Fax: +1 408 414 9201