English
Language : 

EPR-000014 Datasheet, PDF (20/28 Pages) Power Integrations, Inc. – Engineering Prototype Report - 3 W Universal Input TinySwitch-II TNY264 Power Supply
EPR-000014 – 9 V, 0.33 A, 3 W TNY264 Adapter
22-Feb-2002
9.2 DC Output Load Transient Response
Worst case transient measurements were obtained with a Kikusui electronic load and a
Yokogawa DL1540L oscilloscope (20 MHz bandwidth) during output load steps at
265 VAC. The transient response exhibits negligible overshoot.
9.2.1 10% to 50% load change, 265 VAC
VOUT_AC
IOUT
Figure 16. Transient Response 265 VAC 50 Hz, IOUT: 0.03 A to 0.17 A
VOUT & IOUT (100 mV & 200 mA/div, 2 ms/div)
9.2.2 10% to 100% load change, 265 VAC
VOUT_AC
IOUT
Figure 17. Transient Response 265 VAC 50 Hz, IOUT: 0.03 A to 0.33 A
VOUT & IOUT (100 mV & 200 mA/div, 2 ms/div)
Power Integrations, Inc.
Tel: +1 408 414 9200 Fax: +1 408 414 9201
www.powerint.com
Page 20 of 28