GCU08AA-130 Datasheet, PDF (6/7 Pages) Powerex Power Semiconductors – GATE COMMUTATED TURN-OFF THYRISTOR UNIT HIGH POWER INVERTER USE
MITSUBISHI GATE COMMUTATED TURN-OFF THYRISTOR UNIT
GCU08AA-130
HIGH POWER INVERTER USE
PRESS PACK TYPE
Fig. 8 Over voltage fault signal timing chart
Power supply voltage
25V
Maximum Guaranteed Voltage (Note 6)
22V
21V
19V
t1
GDU Voltage bus (G-K Voltage for GCT)
21V
19V
Status Signal
t3
t2
(Note 8)
Control Signal
1 t1 < 1.0ms (Max. repetition rate ; 1 pulse/100ms)
2 t2 ≥ 1.0ms
3 t3 < 0.4sec
Fault signal start System shut down
Control signal off
Note 6. Maximum peak voltage of GDU input voltage from power supply should be lower than 25V.
Note 7. If the period for over voltage < 1.0ms (period t1), no fault signal is sent.
`
If the period for over voltage ≥ 1.0ms, fault signal starts after period t2 from 22V of power supply voltage. System should be shut down (Control signal
should be off) within period t3 from fault signal start.
Note 8. GDU Voltage bus (G-K Voltage for GCT) is clamped to be 21V if power supply voltage is higher than 21V after system shut down (control signal off).