Electrical and Mechanical Characteristics, Tj = 25°C unless otherwise specified
Characteristics
Symbol
Test Conditions
Min.
Typ. Max. Units
Control Sector
Circuit Current (Average)
Input ON Threshold Voltage
Input OFF Threshold Voltage
Input Pull-up Resistor
ID
IDB
Vth(on)
Vth(off)
Ri
Tj = 25°C, VD = 15V, VIN = 5V
Tj = 25°C, VD = VDB = 15V, VIN = 5V
Applied between
—
—
50
mA
—
—
5
mA
0.8
1.4
2.0
Volts
2.5
3.0
4.0
Volts
—
50
—
kΩ
PWM Input Frequency
Arm Shoot-through Blocking Time*
Input Interlock Sensing
Inverter DC-link IGBT Current
Sense Voltage Output Signal**
Inverter DC-link IGBT Current
Sense Voltage Output Limit**
Over-Current Trip Level
fPWM
tDEAD
tint
Vamp 100%
Vamp 200%
Vamp 250%
Vamp 0%
OC
Input Terminal-inside Power Supply
TC ≤ 100°C, Tj ≤ 125°C
Relates to Corresponding Inputs
TC = -20°C ~ 100°C
Relates to Corresponding Input
IC = IOP(100%), VD = 15V, Tj = 25°C
IC = IOP(200%), VD = 15V, Tj = 25°C
IC = IOP(250%), VD = 15V
IC = IOP(0%), VD = 15V
1
—
15
kHz
2.2
—
—
µS
—
100
—
ns
1.5
2.0
2.5
Volts
3.0
4.0
5.0
Volts
5.0
—
—
Volts
—
50
100
mV
31.1 39.0 60.0 Amperes
Over-Current Delay Time
tOC
Short-Circuit Trip Level
SC
Tj = 25°C
—
10
—
µS
—
60
— Amperes
Short-Circuit Delay Time
tSC
—
2
—
µs
Trip Level
UVD
11.0 12.0 13.0 Volts
Supply Circuit
Reset Level
UVDr
11.5 12.5 13.5 Volts
Under-Voltage
Trip Level
UVDB
TC = Tj = 25°C
10.1 10.8 11.6 Volts
Protection
Reset Level
UVDBr
10.6 11.3 12.1 Volts
Delay Time
tdV
—
10
—
µS
Fault Output Pulse Width***
tFO
Tj = 25°C
1.0
1.8
—
mS
Fault Output Current***
IFo(H)
Open Collector Output
—
—
1
µA
IFo(L)
—
—
15
mA
* The dead-time has to be set externally by the CPU; it is not part of the ASIPM internal functions.
**Refer ro the graph on next page.
***Fault output signalling is given only when the internal OC, SC, and UV protection circuits are activated. The OC, SC and UV protection (and fault output) operate for the lower arms only.
The OC and SC protection fault output is given in a pulse format while that of UV protection is maintained thrpughout the duration of the under-voltage condition.