English
Language : 

PS11036 Datasheet, PDF (3/6 Pages) Powerex Power Semiconductors – Intellimod™ Module Application Specific IPM (30 Amperes/600 Volts)
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
PS11036
Intellimod™ Module
Application Specific IPM
30 Amperes/600 Volts
Electrical and Mechanical Characteristics, Tj = 25°C unless otherwise specified
Characteristics
Symbol
Test Conditions
Min.
Typ. Max. Units
IGBT Inverter Sector
Collector-Emitter Saturation Voltage
VCE(sat)
Diode Forward Voltage
VEC
Converter Diode Voltage
VFR
Converter Diode Reverse Current
IRRM
Switching Times
ton
tC(on)
toff
tC(off)
FWDi Reverse Recovery Time
trr
Short Circuit Endurance (Output, Arm, and
Load Short-Circuit Modes)
Switching SOA
IC = 30A, Tj = 25°C, VD = VDB = 15V,
Input = ON (Shunt Voltage Drop Not Included)
Tj = 25°C, -IC = 30A
Tj = 25°C, IFR = 10A
VR = VRRM, Tj = 125°C
1/2 Bridge Inductive, Input = 5V ↔ 0V,
VCC = 300V, IC = 30A, Tj = 125°C,
VD = 15V, VDB = 15V
Note: ton, toff include delay time of
the internal control circuit.
@VCC ≤ 400V, Input = 5V → 0V (One-shot),
-20°C ≤ Tj(start) ≤ 125°C,
13.5V ≤ VD = VDB ≤ 16.5V
@VCC ≤ 400V, Input = 5V → 0V,
Tj ≤ 125°C, IC < OC Trip Level,
13.5V ≤ VD = VDB ≤ 16.5V
—
—
2.9
Volts
—
—
2.9
Volts
—
—
1.5
Volts
—
—
8
mA
0.3
0.6
1.5
µS
—
0.5
1.0
µS
—
1.6
2.5
µS
—
0.5
1.2
µS
—
0.12
—
µS
• No Destruction
• FO Output by Protection Operation
• No Destruction
• No Protecting Operation
• No FO Output
TC Measure Point
TC
TC
3