English
Language : 

BCR30AM Datasheet, PDF (3/4 Pages) Mitsubishi Electric Semiconductor – MEDIUM POWER USE NON-INSULATED TYPE, PLANAR PASSIVATION TYPE
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (412) 925-7272
BCR30AM
Triac
30 Ampere/400-600 Volts
MAXIMUM ON-STATE
CHARACTERISTICS
4.4
TC= 25oC
3.6
2.8
2.0
1.2
0.4
100
101
102
103
INSTANTANEOUS ON-STATE CURRENT, IT, (AMPERES)
MAXIMUM SURGE CURRENT
FOLLOWING RATED LOAD CONDITIONS
500
400
300
200
100
0
100
101
102
CYCLES AT 60 Hz
MAXIMUM ON-STATE
POWER DISSIPATION
50
40
360°
CONDUCTION
30
RESISTIVE,
INDUCTIVE
LOADS
20
10
0
0
10 20 30 40 50
RMS ON-STATE CURRENT, IT(RMS), (AMPERES)
2.0102
TRANSIENT THERMAL
IMPEDANCE CHARACTERISTICS
103
1.6
1.2
0.8
0.4
0
10-1
100
101
102
CYCLES AT 60 Hz
ALLOWABLE CASE TEMPERATURE
VS. RMS ON-STATE CURRENT
160
140
120
100
80
360°
CONDUCTION
RESISTIVE,
INDUCTIVE
LOADS
60
FOR AC CONTROL
40 THIS GRAPH NEARLY
APPLIES REGARDLESS
20 OF THE CONDUCTION
ANGLE
0
0
10
20
30
40
RMS ON-STATE CURRENT, IT(RMS), (AMPERES)
GATE TRIGGER CURRENT
VS. JUNCTION TEMPERATURE
(TYPICAL)
103
GATE CHARACTERISTICS
(I, II, III)
102
101 VGM = 10V
VGT = 2.5V
PG(avg) = 0.5W
PGM = 5W
100
IRGT I,
IFGT I,
IRGT III
IGM = 2A
10-1
VGD = 0.2V
101
102
103
104
GATE CURRENT, IG, (mA)
ALLOWABLE AMBIENT TEMPERATURE
VS. RMS ON-STATE CURRENT
160
FIN: A PLATE PAINTED BLACK
140
WITH GREASE
CURVES APPLY REGARDLESS
120
OF THE CONDUCTION ANGLE
RESISTIVE,
100
INDUCTIVE LOADS
NATURAL CONVECTION
80
120 x 120 x t 2.3
100 x 100 x t 2.3
60
160 x 160 x t 2.3
40
20
0
0
10
20
30
40
RMS ON-STATE CURRENT, IT(RMS), (AMPERES)
GATE TRIGGER VOLTAGE
VS. JUNCTION TEMPERATURE
(TYPICAL)
103
102
IRGT I, IRGT III
IFGT I
102
101
-60 -40 -20 0 20 40 60 80 100 120 140
JUNCTION TEMPERATURE, Tj, (°C)
101
-60 -40 -20 0 20 40 60 80 100 120 140
JUNCTION TEMPERATURE, Tj, (°C)
T-89