English
Language : 

PS-DA0284-01 Datasheet, PDF (2/3 Pages) Power Systems GmbH+Co.KG – DC-AC INVERTER UNIT 11 W DUAL OUTPUTS
DC-AC INVERTER UNIT
PS-DA0284-01(S) (11 W DUAL OUTPUTS)
(PRELIMINARY INFORMATION)
Table 1
Set 1 CN 1-7 Set 2 CN 1-8 Nominal output current
Open*
Open*
8.0 mArms
Open*
GND
7.0 mArms
GND
Open*
6.0 mArms
GND
GND
5.0 mArms
* If driven by a logic signal it should be open collector or drain only, not a voltage source
ELECTRICAL CHARACTERISTICS :
Parameters
Conditions
Symbols
Vin (V) Vbr (V) Tu (°C)
Specification
Min. Typ. Max.
Output Current
Iout 12±1.2 0 -20~+70 4.4
5.0
5.6
Output Current
Iout 12±1.2 0 -20~+70 5.4
6.0
6.6
Output Current
Iout 12±1.2 0 -20~+70 6.4
7.0
7.6
Output Current
Iout 12±1.2 0 -20~+70 7.4
8.0
8.6
Output Current
Iout 12±0.6 5 -20~+70 -
13
-
Input Current
Iin 12±1.2 0 -20~+70 -
0.95 1.23
Frequency
F 12±1.2 0 -20~+70 45
50
55
Open Circuit Voltage Vopen 11.4
0 -20~+70 1.600 1.800 2.000
No load Shutdown
Tsd 12±1.2 0 -20~+70 -
1.0
-
Unit
m Arm s
m Arm s
m Arm s
m Arm s
%
Adc
kHz
Vrm s
sec
Note
Dut y 100%
Dut y 100%
Dut y 100%
Dut y 100%
Dut y M in
wit hout load
Note 1 :
Note 2:
Note 3:
Please keep minimum of 2mm clearance (all directions) between inverter high voltage area as
marked on mechanical drawing and any conductors.
Before apply any control signal into inverter, please provide Vcc first. Please follow the reversed
sequence during power off. Power off control signal first, then power off Vcc.
CN 1-6 can also used with external PWM signal. The external PWM frequency should be in a range
of 200 ~ 500Hz. For other frequency please request. The Low level is defined by 0 ~ 0.3 Vdc and the
high level is defined by 2.2 ~ 5.0 Vdc.
CONNECTOR/PINNING/ORDER KEY :
Pinning
Model
Connector
Pinning
Connector CN2 CN3
DA0284-01-1-x 2x SM02(8.0) 1=H, 2=N.C, 3=L CN2+CN3
1;3
1;3
DA0284-01-2-x 2x SM02 B-BHSS 1=H, 2=L
CN2+CN3
1;2
3;4
Model
Function of dimming
Level
DA0284-01-x-1 Dimming external PWM-signal (70Khz)
DA0284-01-x-2
Analog dimming (0~5Vdc)
0Vdc max. brightness
Power Systems – The Power Solution
Web:
www.Power-Systems.de
Email:
Info@Power-Systems.de
All specifications are subject to change without notice.
Page (2)
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. : + 49 / 70 62 / 67 59 - 6
Fax: + 49 / 70 62 / 67 59 - 800
Version 1.6.8, 12th January 2010