English
Language : 

PS-DA0284-01 Datasheet, PDF (1/3 Pages) Power Systems GmbH+Co.KG – DC-AC INVERTER UNIT 11 W DUAL OUTPUTS
DC-AC INVERTER UNIT
PS-DA0284-01(S) (11 W DUAL OUTPUTS)
DESCRIPTION :
This low profile DC to AC Inverter is developed
for dual lamps.
APPLICABLE LCD:
6.4 to 15 inches double lamp type
Lamp Voltage 687 Vrms
Lamp Current 2 x 5 ~ 8 mArms
Lamp Start Up Voltage 1.800 Vrms (Vin : 12 Vdc)
FEATURES :
Remote ON/OFF
Open Lamp Detection
RoHS compliant (S)
TEMPERATURE & HUMIDITY :
Operating Temperature Range
Storage Temperature Range
Humidity
-20°C ~ +70°C
-40°C ~ +85°C
95 %RH max
DIMENSIONS :
L x W x H 165 x 21 x 9.5 mm
(PRELIMINARY INFORMATION)
Unit : mm
Weight :24,0 (g) typ.
Components
No.
1
2
3
Note: Please use plastic screw in case of a non-insulating mounting base!
Part Description
Qty.
PCB
1
Connector CN1
1
Connector CN2 + CN3
2
Material
UL94V-0 (FR-4 or CEM-3)
53261-0871
SM02(8.0)B-BHS-1-TB
Note
t=1m m
Molex or equal
JST or equal
Input side CN1:
Pin No. Symbols
CN 1-1+2 Vin
CN 1-3+4 GND
CN 1-5 Vrmt
CN 1-6 Vbr
CN 1-7 Set 1
CN 1-8 Set 2
Ratings
10.8 ~ 13.2 Vdc
-
0 ~ 0.4 = OFF / 2.0 ~ Vin = ON
Please look on page 3
See table 1 settings
See table 1 settings
Power Systems – The Power Solution
Web:
www.Power-Systems.de
Email:
Info@Power-Systems.de
All specifications are subject to change without notice.
Page (1)
Output side CN2:
Pin No. Symbols
CN 2-1 Vhigh
CN 2-2
CN 2-3
Vlow
Ratings
687 Vrms (5~8 mArms)
(GND)
Output side CN3:
Pin No. Symbols
CN 3-1 Vhigh
CN 3-2
CN 3-3
Vlow
Ratings
687 Vrms (5~8 mArms)
(GND)
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. : + 49 / 70 62 / 67 59 - 6
Fax: + 49 / 70 62 / 67 59 - 800
Version 1.6.8, 12th January 2010