English
Language : 

CPD200-4530 Datasheet, PDF (5/13 Pages) Power-One – 200 - 250 Watt CompactPCI DC-DC Converters
CPD Series Data Sheet
200 – 250 Watt CompactPCI® DC-DC Converters
®
Table 4b: Output data for Vo3, Vo4
Output
Characteristics
Conditions
Vo Output voltage
Io nom Nominal output current
Vi nom, 50% Io nom
Io max Max. output current
IoL Output current limit
Vi min – Vi max
TC min – TC max
Io min Minimum load
vo Output Switch. frequ. Vi nom, Io nom
voltage
BW = 20 MHz
noise
Total
Cext = 22 µF + 100 nF
∆VoV Static line regulation
Vi min – Vi max, Io nom
∆VoL Static load regulation
Vi nom, 50 – 100% Io max
∆VoS Overshoot at switch on/off
vo d Dynamic Voltage
Vo3: ∆Io = 2 A, dIo/dt = 2 A/µs
load
deviation
Vo4: ∆Io = 0.5 A, dIo/dt = 2 A/µs
td regulation Recovery time
αVo Temperature coefficient TC min – TC max
of output voltage
0 – Io nom, Vi min – Vi max
th Hold-up time
starting at Vi nom, Io nom
ts Start-up time
Vi nom, Io nom
Vo3
12 V
min typ max
11.88 12.0 12.12
2.5/41
5.5
7
Io3 > 75% Io42
±60
±120
0
120
± 200
500
±0.3
4
150 200
Vo4
–12 V
min typ max
–11.52 –12.0 –12.48
0.5/11
2
3.5
no min. load required
±60
– 480 3
0
120
± 200
500
±0.5
4
150 200
Unit
VDC
A
mVpp
mV
µs
mV/K
ms
1 Values for CPD200/CPD250 2 Required to maintain regulation of Vo4 3 Droop characteristic for passive current sharing
Hold-up Time
For extended hold-up time, use external output capacitors
or decoupling diodes and input capacitors of adequate
size.
Formula for additional external input capacitor
Ci ext = –2–•–P–η–o–••–((V–th–ti2t–o–t–al–V––i –mth–in)–2•)–1–0–0–
where as:
C i ext
Po
η
= external input capacitance [mF]
= output power [W]
= efficiency [%]
th total = total hold-up time [ms]
th
= hold-up time [ms]
Vi min = minimum input voltage [V]
Vt i
= threshold level [V]
All outputs have a constant current limitation with a
rectangular characteristic (see figure below). The total
current from the main power trains Vo1, Vo2 and Vo3 is
limited by Po max. So there is a free choice of load
distribution between these outputs.
Vo/Vo nom
1.0
0.95
Io nom
Io max
Io L
05186a
0.5
Hot Swap
Hot swap is possible. Using the hot-swap capability, the
0
Io
output voltages may deviate dynamically by max. 5%
during the plug-in / plug-out operations.
Fig. 2
Output Protection and Current Limitation
Current limitation behavior of a CPD.
The outputs are fully protected against continuous open
circuit (no load) and also against continuous short circuit.
NOV 28, 2006 revised to JAN 29, 2007
Page 5 of 13
www.power-one.com