English
Language : 

CPD200-4530 Datasheet, PDF (4/13 Pages) Power-One – 200 - 250 Watt CompactPCI DC-DC Converters
CPD Series Data Sheet
200 – 250 Watt CompactPCI® DC-DC Converters
®
Electrical Output Data
General Conditions:
– TA = 25 °C, unless Tc is specified.
– CPD200: 250 LFM (1.25 m/s), CPD250: 400 LFM (2 m/s),
– Sense lines connected directly at the connector.
Table 4a: Output data for Vo1, Vo2
Output
Characteristics
Conditions
Vo Output voltage
Io nom Nominal output current
Vi nom, 50% Io nom
Io max Max. output current
IoL Output current limit
Vi min – Vi max
TC min – TC max
Io min Minimum load
vo Output Switch. frequ. Vi nom, Io nom
voltage
BW = 20 MHz
noise
Total
Cext = 22 µF + 100 nF
∆VoV Static line regulation
Vi min – Vi max, Io nom
∆VoL Static load regulation
Vi nom, 50 – 100% Io max
∆VoS Overshoot at switch on/off
vo d Dynamic Voltage
load
deviation
td
regulation Recovery
time
Vo1: ∆Io = 10 A, dIo/dt = 2 A/µs
Vo2: ∆Io = 10 A, dIo/dt = 2 A/µs
αVo Temperature coefficient TC min – TC max
of output voltage
0 – Io nom, Vi min – Vi max
th Hold-up time
starting at Vi nom, Io nom
ts Start-up time
Vi nom, Io nom
Vo1
5.0 V
min typ max
4.95 5.0 5.05
20/25 1
40
50
no min. load required
60
±25
±50
0
± 120
100
±0.3
4
150 200
Vo2
3.3 V
min typ max
3.267 3.3 3.333
20
40
50
no min. load required
60
±18
±33
0
± 120
100
±0.2
4
150 200
1 CPD200: 20 A, CPD250: 25 A
Unit
VDC
A
mVpp
mV
µs
mV/K
ms
NOV 28, 2006 revised to JAN 29, 2007
Page 4 of 13