English
Language : 

DP8105 Datasheet, PDF (4/35 Pages) Power-One – 8V to 14V Input , 0.7V to 5.5V Output
DP8105 5A DC-DC Intelligent dPOL Data Sheet
8V to 14V Input • 0.7V to 5.5V Output
4.3 Protection Specifications
Parameter
Type
Threshold
Threshold Accuracy
Type
Threshold
Threshold Accuracy
Delay
Turn Off Behavior3
Type
Threshold
Threshold Accuracy
Delay
Turn Off Behavior3
Type
Turn Off Threshold
Turn On Threshold
Threshold Accuracy
Delay
Turn Off Behavior3
Conditions/Description
Min
Nom
Max
Output Overcurrent Protection
Default
Programmable
Default
Programmable in 11 steps
Non-Latching, 130ms period
Latching/Non-Latching
132
36
132
-20
+20
Output Overvoltage Protection
Default
Programmable
Default
Programmable in 10% steps
Measured at VO.SET=2.5V
From instant when threshold is exceeded until
the turn-off command is generated
Default
Programmable to
Non-Latching, 130ms period
Latching/Non-Latching
130
110
130
-2
2
6
Emergency Off
Critical Off / Emergency Off
Output Undervoltage Protection
Default
Programmable
Default
Programmable in 5% steps
Measured at VO.SET=2.5V
From instant when threshold is exceeded until
the turn-off command is generated
Default
Programmable to
Non-Latching, 130ms period
Latching/Non-Latching
75
75
90
-2
2
6
Sequenced Off
Sequenced / Critical Off
Overtemperature Protection
Default
Programmable
Non-Latching, 130ms period
Latching/Non-Latching
Temperature is increasing
120
Temperature is decreasing after the module was
shut down by OTP4
110
-5
5
From instant when threshold is exceeded until
the turn-off command is generated
Default
Programmable to
6
Sequenced Off
Sequenced / Critical Off
Tracking Protection (when Enabled)
Units
%IOUT
%IOUT
%IOCP.SET
%VO.SET
%VO.SET
%VOVP.SET
µs
%VO.SET
%VO.SET
%VUVP.SET
µs
°C
°C
°C
µs
3 Sequenced Off: The turn-off follows the turn-off delay and slew-rate settings; Critical Off: At turn-off both low and high switches are
immediately disabled; Catastrophic Off: At turn-off the high side switch is disabled and the low side switch is enabled.
4 OTP clears when Overtemp Warning (Status Register TW bit) turns off.
BCD.00261 Rev. 1.0, 12 Feb 2013
www.power-one.com
Page 4 of 35