English
Language : 

70IMX35D05D15-8 Datasheet, PDF (4/15 Pages) Power-One – IMX35 Series Data Sheet 35 Watt Quad-Output DC-DC Converters
IMX35 Series Data Sheet
35 Watt Quad-Output DC-DC Converters
®
Electrical Input Data
General conditions:
TA = 25 °C, unless specified
Pins 8 (shutdown or i), 6 (W), 5 (Trim or Trim1), and 1 (PUL) left open-circuit (not connected), unless specified.
Table 2: Input Data
Input
Characteristics
Vi
Vi nom
Vi sur
t start-up
Input voltage range 1
Nominal input voltage
Repetitive surge voltage
Converter
Switch on
start-up time 2 S¯¯D high
t rise
Rise time 3
Ii o
No load input current
Iirr
Reflected ripple current
Iinr p
Inrush peak current 4
Ci
Input capacitance
VS–D–
Shut down voltage
RS–D–
Shutdown input resistance
I
––
SD
Input current during shutdown
fs
Switching frequency
Conditions
TA min to TA max
Io = 0 to Io nom
Abs. max input (3 s)
Worst case condition at
Vi min and full load
Vi nom resist load
Io nom capac. load
Io = 0, Vi min to Vi max
Io = 0 to Io nom
Vi = Vi nom
for surge calculation
Converter disabled
Converter operating
Vi min to Vi max
Vi min to Vi max, Io = 0 to Io nom
20 IMX35
min typ max
92
36
20
40
0.25 0.5
0.1
3
6 12
70
30
8
2
–10 to 0.7
open circuit or 2 to 20
approx. 10
12
220 240
40 IMX35
min typ max
18 2
75
40
100
0.25 0.5
0.1
3
6 12
50
30
9
1.3
–10 to 0.7
open circuit or 2 to 20
approx. 10
6
220 240
Unit
VDC
s
ms
mA
mApp
A
µF
V
kΩ
mA
kHz
Input
Characteristics
Vi
Vi nom
Vi sur
t start-up
Input voltage range 1
Nominal input voltage
Repetitive surge voltage
Converter
Switch on
start-up time 2 S¯¯D high
t rise
Rise time 3
Ii o
No load input current
Iirr
Reflected ripple current
Iinr p
Inrush peak current 4
Ci
Input capacitance
VS–D–
Shut down voltage
R
––
SD
Shutdown input resistance
I
––
SD
Input current during shutdown
fs
Switching frequency
Conditions
TA min to TA max
Io = 0 to Io nom
Abs. max input (3 s)
Worst case condition at
Vi min and full load
Vi nom resist load
Io nom capac. load
Io = 0, Vi min to Vi max
Io = 0 to Io nom
Vi = Vi nom
for surge calculation
Converter disabled
Converter operating
Vi min to Vi max
Vi min to Vi max, Io = 0 to Io nom
70 IMX35
min typ max
40 2
121
70
150
0.25 0.5
0.1
3
6 12
30
30
7
0.5
–10 to 0.7
open circuit or 2 to 20
approx. 10
5
220 240
110 IMX35
min typ max
60 2
150 5
110
170
0.4 0.7
0.1
3
6 12
20
30
7
0.5
–10 to 0.7
open circuit or 2 to 20
approx. 10
5
220 240
Unit
VDC
s
ms
mA
mApp
A
µF
V
kΩ
mA
kHz
1 Vi min will not be as stated, if Vo is increased above Vo nom by
use of Trim input. If the output voltage is set to a higher value,
Vi min will be proportionately increased.
2 Input undervoltage lockout at typ. 85% of Vi min.
3 Measured with resistive and max. admissible capacitive load.
4 Source impedance according to ETS 300132-2, version 4.3.
5 154 V during 2 s
BCD20009-G Rev AC, 06-May-2013
Page 4 of 15