English
Language : 

70IMX35D05D15-8 Datasheet, PDF (15/15 Pages) Power-One – IMX35 Series Data Sheet 35 Watt Quad-Output DC-DC Converters
IMX35 Series Data Sheet
35 Watt Quad-Output DC-DC Converters
®
Table 17: Electric strength test voltages
Characteristic
Factory test >1 s
Equivalent DC voltage
Input to
(outputs+case)
20/40IMX35 1
1.2
1.5
Input to
(outputs+case)
70/110IMX35 1
1.8
2.5
Outputs to
case
all models 1
0.5
0.7
Insulation resistance
>100
>100
–
at 500 VDC
1 For open-frame models (option Z), only the insulation input to outputs is tested.
2 The test voltage between outputs is not applied as routine test.
Between
outputs
all models
0.15 2
0.2 2
–
Unit
kVAC
kVDC
MΩ
Isolation
The electric strength test is performed in the factory as a
routine test in accordance with EN 50116, EN 60950, and UL
60950 and should not be repeated in the field. Power-One will
not honor any warranty claims resulting from electric strength
field tests.
Options
i: Inhibit (Negative Shutdown Logic)
The outputs of the converter may be enabled or disabled by
means of a logic signal (TTL, CMOS, etc.) applied to the inhibit
pin 8. If the inhibit function is not required the inhibit (pin 8)
4 Vi+
8i
2 Vi –
06138a
Fig. 19
If the inhibit pin is not used, connect it to Vi–.
should be connected to Vi– to enable the output (active low
logic, fail safe).
Voltage at pin 8:
Converter operating:
Converter disabled:
–10 V to 0.8 V
2.4 V to 20 V or left
open-circuit
Z: Open Frame
For applications, where the protection by a housing is not
necessary or in the case that the motherboard should be
lacquered after fitting the converter.
Note: The converters shall not be exposed to cleaning processes,
as this will damage the glue of the ferrite cores.
G: RoHS-6
Converters with a type designation ending by G are RoHS-
compliant for all six substances.
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical
components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written
consent of the respective divisional president of Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on
the date manufactured. Specifications are subject to change without notice.
BCD20009-G Rev AC, 06-May-2013