English
Language : 

PL611-01 Datasheet, PDF (3/6 Pages) PhaseLink Corporation – Programmable Quick Turn Clock
PL611-01
Programmable Quick Turn ClockTM
ELECTRICAL SPECIFICATIONS
ABSOLUTE MAXIMUM RATINGS
PARAMETERS
SYMBOL
MIN.
MAX.
UNITS
Supply Voltage Range
Input Voltage Range
Output Voltage Range
Soldering Temperature (Green package)
Data Retention @ 85°C
VDD
-0.5
4.6
V
VI
-0.5
VDD+0.5
V
VO
-0.5
VDD+0.5
V
260
°C
10
Year
Storage Temperature
TS
-65
150
°C
Ambient Operating Temperature
-40
85
°C
Exposure of the device under conditions beyond the limits specified by Maximum Ratings for extended periods may cause permanent damage to the device
and affect product reliability. These conditions represent a stress rating only, and functional operations of the device at these or any other conditions above
the operational limits noted in this specification is not implied.
AC SPECIFICATIONS
PARAMETERS
CONDITIONS
MIN. TYP. MAX. UNITS
Crystal Input Frequency(XIN)
Fundamental Crystal
3rd Overtone Crystal
10
30
MHz
75
MHz
Input (FIN) Frequency
200
MHz
Input (FIN) Signal Amplitude
Internally AC coupled
0.9
VDD
Vpp
PLL Settling Time
After Crystal Start Up (Crystal Input)
After Reference Input Present (FIN)
100
µs
100
µs
Output Rise Time
15pF Load, 10/90%VDD, Standard drive
15pF Load, 10/90%VDD, High drive
2.5
3.5
ns
1.0
1.5
ns
Output Fall Time
15pF Load, 90/10%VDD, Standard drive
15pF Load, 90/10%VDD, High drive
2.5
3.5
ns
1.0
1.5
ns
Duty Cycle
At VDD/2
45
50
55
%
Max. output skew between
same frequency clocks
Equal loading (15 pF). Equal frequency
& drive strength
500
ps
Period Jitter, peak-to-peak*
(measured from 10,000
samples)
With capacitive decoupling between VDD
and GND. Operating only one output.
70
ps
* Note: Jitter performance depends on the programming parameters.