ELECTRICAL SPECIFICATIONS
PL611-07
Programmable Quick Turn ClockTM
ABSOLUTE MAXIMUM RATINGS
PARAMETERS
SYMBOL
MIN.
MAX.
UNITS
Supply Voltage Range
VDD
-0.5
4.6
V
Input Voltage Range
VI
-0.5
VDD+0.5
V
Output Voltage Range
VO
-0.5
VDD+0.5
V
Soldering Temperature (Green package)
260
°C
Data Retention @ 85°C
10
Year
Storage Temperature
TS
-65
150
°C
Ambient Operating Temperature
-40
85
°C
Exposure of the device under conditions beyond the limits specified by Maximum Ratings for extended periods may cause permanent damage to the device
and affect product reliability. These conditions represent a stress rating only, and functional operations of the device at these or any other conditions above
the operational limits noted in this specification is not implied.
AC SPECIFICATIONS
PARAMETERS
Crystal Input Frequency(XIN)
CONDITIONS
Fundamental Crystal
MIN. TYP. MAX. UNITS
10
30
MHz
Input (FIN) Frequency
100 MHz
Input (FIN) Signal Amplitude
Internally AC coupled
0.9
VDD Vpp
Settling Time
At power-up (after VDD increases over 1.62V)
10
ms
Output Rise Time
15pF Load, 10/90%VDD, Standard drive
15pF Load, 10/90%VDD, High drive
2.5
3.5
ns
1.0
1.5
ns
Output Fall Time
15pF Load, 90/10%VDD, Standard drive
15pF Load, 90/10%VDD, High drive
2.5
3.5
ns
1.0
1.5
ns
Duty Cycle
At VDD/2
45
50
55
%
Period Jitter, peak-to-peak*
With capacitive decoupling between VDD and
(measured from 10,000 samples) GND. Operating only one output.
* Note: Jitter performance depends on the programming parameters.
70
ps