PAS302BCW-22S
CMOS Image Sensor IC
4.2 Output Timing
VGA mode ( 644 x 488 ) pixel readout:
H_Start[9:0] = 0,
V_Start[8:0] = 0,
Nov_By2[7:0] = 87,
H_Size[9:0] = 643,
V_Size[8:0]= 487,
/PW4J[F/PW@#Z  1JYDMLT EFGBVMU
-JOFUJNF/PW4J[F 1JYDMLT EFGBVMU
)TZOD
(3( 3
# (# (
# (# (
/PW4J[F
1JYDML
7BMJEQJYFM1JYDMLT
Figure 4.2 Inter-line timing ( default )
(3(3
If Mask_Dark[3] = 0,
7TZOD
'SBNF5JNF-1' -JOF EFGBVMU
)TZOD
%BSL %BSL %BSL %BSL
%BSL
%BSL-JOF-JOF
7BMJE-JOF-JOF
Figure 4.3 Inter-frame timing (LPF default setting = 487, Mask_Dark[3] =0)
If Mask_Dark[3] = 1,
7TZOD
'SBNF5JNF-1' -JOF EFGBVMU
)TZOD
%BSL-JOF-JOF
7BMJE-JOF-JOF
Figure 4.4 Inter-frame timing (LPF default setting = 487, Mask_Dark[3] =1)
4.3 Hardware Windowing
Users are allowed to define window size as well as window location in PAS302BCW-22S,
Window size can range from 20x14 to 644x484. The location of window can be anywhere in the
sensor array. Window location and size is defined by register H_Start, V_Start, H_Size and
V_Size; the H_Start defines the starting column while V_Start defines the starting row of the
window; the H_Size define the column width of the window and V_Start define the row depth of
the window.
4.4 Sub-sampling
PAS302BCW-22S can be programmed to output image in QVGA and QQVGA size by setting
Registers Skip_Digital or Skip_Analog. In QVGA sub-sampling mode, both vertical and
horizontal pixels are sub-sampling at 1/2, while in QQVGA sub-sampling mode, both vertical
and horizontal pixels are sub-sampling at 1/4. The maximum sub-sampling rate is 1/16.
Version 2.4, 20 Sep. 2005
PixArt Imaging Inc.
6
E-mail: fae_service@pixart.com.tw