Table 7. Static characteristics …continued
At recommended operating conditions; voltages are referenced to GND (ground = 0 V).
Symbol Parameter
Conditions
Min
ΔIOFF additional power-off leakage VI or VO = 0 V to 3.6 V;
-
current
VCC = 0 V to 0.2 V
ICC
supply current
VI = GND or VCC; IO = 0 A;
-
VCC = 0.8 V to 3.6 V
ΔICC
additional supply current
VI = VCC − 0.6 V; IO = 0 A;
-
VCC = 3.3 V
12. Dynamic characteristics
Typ Max
Unit
-
±0.75
μA
-
1.4
μA
-
75
μA
Table 8. Dynamic characteristics
Voltages are referenced to GND (ground = 0 V); for test circuit see Figure 9.
Symbol Parameter
Conditions
25 °C
Min Typ[1] Max
CL = 5 pF
tpd
propagation delay
CL = 10 pF
tpd
propagation delay
CL = 15 pF
tpd
propagation delay
CL = 30 pF
A to Y; see Figure 8
VCC = 0.8 V
VCC = 1.1 V to 1.3 V
VCC = 1.4 V to 1.6 V
VCC = 1.65 V to 1.95 V
VCC = 2.3 V to 2.7 V
VCC = 3.0 V to 3.6 V
A to Y; see Figure 8
VCC = 0.8 V
VCC = 1.1 V to 1.3 V
VCC = 1.4 V to 1.6 V
VCC = 1.65 V to 1.95 V
VCC = 2.3 V to 2.7 V
VCC = 3.0 V to 3.6 V
A to Y; see Figure 8
VCC = 0.8 V
VCC = 1.1 V to 1.3 V
VCC = 1.4 V to 1.6 V
VCC = 1.65 V to 1.95 V
VCC = 2.3 V to 2.7 V
VCC = 3.0 V to 3.6 V
[2]
-
2.7
2.6
2.1
2.0
1.9
19.9 -
5.9 11.0
4.3 6.6
3.7 5.4
3.0 4.1
2.8 3.6
[2]
-
2.9
2.8
2.7
2.3
2.1
23.4 -
6.8 12.7
5.0 7.7
4.2 6.2
3.6 4.8
3.3 4.3
[2]
-
3.3
3.3
2.8
2.7
2.6
26.9 -
7.6 14.3
5.5 8.6
4.7 7.0
4.0 5.5
3.8 4.8
−40 °C to +125 °C
Unit
Min Max
Max
(85 °C) (125 °C)
-
-
2.4 11.1
2.4
7.1
2.0
6.0
1.7
4.5
1.5
3.9
-
ns
11.2 ns
7.4 ns
6.2 ns
4.7 ns
4.0 ns
-
-
2.8 12.8
2.6
8.2
2.5
6.7
2.1
5.2
2.0
4.5
-
ns
12.9 ns
8.6 ns
7.1 ns
5.5 ns
4.7 ns
-
-
3.0 14.5
2.9
9.4
2.8
7.7
2.4
5.9
2.2
5.2
-
ns
14.7 ns
9.8 ns
8.1 ns
6.2 ns
5.4 ns
74AUP1G14
Product data sheet
All information provided in this document is subject to legal disclaimers.
Rev. 6 — 28 June 2012
© NXP B.V. 2012. All rights reserved.