English
Language : 

74HC4066_2004 Datasheet, PDF (6/27 Pages) NXP Semiconductors – Quad bilateral swiches
Philips Semiconductors
Quad bilateral switches
Product specification
74HC4066; 74HCT4066
RECOMMENDED OPERATING CONDITIONS
SYMBOL
PARAMETER
CONDITIONS
VCC
VI
VS
Tamb
tr, tf
supply voltage
input voltage
switch voltage
ambient temperature
input rise and fall times
see DC and AC
characteristics
per device
VCC = 2.0 V
VCC = 4.5 V
VCC = 6.0 V
VCC = 10.0 V
74HC4066
74HCT4066
UNIT
MIN. TYP. MAX. MIN. TYP. MAX.
2.0 5.0
GND −
GND −
−40 +25
−40 −
10.0 4.5 5.0
VCC GND −
VCC GND −
+85 −40 +25
+125 −40 −
5.5 V
VCC V
VCC V
+85 °C
+125 °C
−
6.0 1000 −
6.0 500 ns
−
−
500 −
−
−
ns
−
−
400 −
−
−
ns
−
−
250 −
−
−
ns
LIMITING VALUES
In accordance with the Absolute Maximum Rating System (IEC 60134); voltages are referenced to GND (ground = 0 V).
SYMBOL
PARAMETER
VCC
IIK
ISK
IS
ICC, IGND
Tstg
Ptot
PS
supply voltage
input diode current
switch diode current
switch current
VCC or GND current
storage temperature
power dissipation
power dissipation per switch
CONDITIONS
VI < −0.5 V or VI > VCC + 0.5 V
VS < −0.5 V or VS > VCC + 0.5 V
−0.5 V < VO < VCC + 0.5 V; note 1
Tamb = −40 °C to +125 °C; note 2
MIN.
−0.5
−
−
−
−
−65
−
−
MAX.
+11.0
±20
±20
±25
±50
+150
500
100
UNIT
V
mA
mA
mA
mA
°C
mW
mW
Notes
1. To avoid drawing VCC current out of pin nZ, when switch current flows in pin nY, the voltage drop across the
bidirectional switch must not exceed 0.4 V. If the switch current flows into pin nZ, no VCC current will flow out of
pin nY. In this case there is no limit for the voltage drop across the switch, but the voltages at pins nY and nZ may
not exceed VCC or GND.
2. For DIP14 packages: above 70 °C derate linearly with 12 mW/K.
For SO14 packages: above 70 °C derate linearly with 8 mW/K.
For SSOP14 and TSSOP16 packages: above 60 °C derate linearly with 5.5 mW/K.
For DHVQFN14 packages: above 60 °C derate linearly with 4.5 mW/K.
2004 Nov 11
6