English
Language : 

SA5209 Datasheet, PDF (4/17 Pages) NXP Semiconductors – Wideband variable gain amplifier
Philips Semiconductors
Wideband variable gain amplifier
Product specification
SA5209
DC ELECTRICAL CHARACTERISTICS
TA = 25oC, VCC1 = VCC2 = +5.0V, VAGC = 1.0V, unless otherwise specified.
SYMBOL
PARAMETER
LIMITS
TEST CONDITIONS
UNIT
MIN
TYP
MAX
RBG
VAGC
IBAGC
Bandgap loading
AGC DC control voltage range
AGC pin DC bias current
Over temperature1
2
10
kΩ
Over temperature1
0-1.3
V
0V<VAGC<1.3V
Over temperature1
-0.7
-6
µA
-10
NOTES:
1. “Over Temperature Range” testing is as follows:
SA is -40 to +85°C
At the time of this data sheet release, the D package over-temperature data sheet limits are guaranteed via guardbanded room temperature
testing only.
AC ELECTRICAL CHARACTERISTICS
TA = 25oC, VCC1 = VCC2 = +5.0V, VAGC = 1.0V, unless otherwise specified.
SYMBOL
PARAMETER
LIMITS
TEST CONDITIONS
UNIT
MIN
TYP
MAX
BW
-3dB bandwidth
600
850
Over temperature1
500
MHz
GF
Gain flatness
DC - 500MHz
Over temperature1
+0.4
dB
+0.6
VIMAX
Maximum input voltage swing (single-ended) for
linear operation2
200
mVP-P
VOMAX
NF
VIN-EQ
Maximum output voltage swing (single-ended)
for linear operation2
Noise figure (unmatched configuration)
Equivalent input noise voltage spectral density
RL = 50Ω
RL = 1kΩ
RS = 50Ω, f = 50MHz
f = 100MHz
400
mVP-P
1.9
VP-P
9.3
dB
2.5
nV/√Hz
S12
Reverse isolation
f = 100MHz
-60
dB
∆G/∆VCC
∆G/∆T
Gain supply sensitivity (single-ended)
Gain temperature sensitivity
RL = 50Ω
0.3
0.013
dB/V
dB/°C
CIN
BWAGC
PO-1dB
PI-1dB
Input capacitance (single-ended)
-3dB bandwidth of gain control function
1dB gain compression point at output
1dB gain compression point at input
f = 100MHz
f = 100MHz, VAGC
=0.1V
2
pF
20
MHz
-3
dBm
-10
dBm
IP3OUT
Third-order intercept point at output
f = 100MHz, VAGC
>0.5V
+13
dBm
IP3IN
Third-order intercept point at input
f = 100MHz, VAGC
<0.5V
+5
dBm
∆GAB
Gain match output A to output B
f = 100MHz, VAGC = 1V
0.1
dB
NOTE:
1. “Over Temperature Range” testing is as follows:
SA is -40 to +85°C
At the time of this data sheet release, the D package over-temperature data sheet limits are guaranteed via guardbanded room temperature
testing only.
2. With RL > 1kΩ, overload occurs at input for single-ended gain < 13dB and at output for single-ended gain > 13dB. With RL = 50Ω, overload
occurs at input for single-ended gain < 6dB and at output for single-ended gain > 6dB.
1997 Nov 07
4