MB2373 Datasheet, PDF (4/11 Pages) NXP Semiconductors – Dual octal transparent latch 3-State | |||
|
◁ |
Philips Semiconductors Advanced BiCMOS Products
Dual octal transparent latch (3-State)
Product specification
MB2373
RECOMMENDED OPERATING CONDITIONS
SYMBOL
PARAMETER
VCC
VI
VIH
VIL
IOH
IOL
ât/âv
Tamb
DC supply voltage
Input voltage
High-level input voltage
Low-level Input voltage
High-level output current
Low-level output current
Input transition rise or fall rate
Operating free-air temperature range
LIMITS
MIN
MAX
4.5
5.5
0
VCC
2.0
0.8
â32
64
0
10
â40
+85
UNIT
V
V
V
V
mA
mA
ns/V
°C
DC ELECTRICAL CHARACTERISTICS
LIMITS
SYMBOL
PARAMETER
TEST CONDITIONS
Tamb = +25°C
Tamb = â40°C
to +85°C
UNIT
MIN TYP MAX MIN MAX
VIK
Input clamp voltage
VCC = 4.5V; IIK = â18mA
â0.9 â1.2
â1.2 V
VCC = 4.5V; IOH = â3mA; VI = VIL or VIH
2.5 2.9
2.5
V
VOH High-level output voltage
VCC = 5.0V; IOH = â3mA; VI = VIL or VIH
3.0 3.4
3.0
V
VCC = 4.5V; IOH = â32mA; VI = VIL or VIH
2.0 2.4
2.0
V
VOL Low-level output voltage
VCC = 4.5V; IOL = 64mA; VI = VIL or VIH
0.42 0.55
0.55 V
VRST Power-up output voltage3
VCC = 5.5V; IO = 1mA; VI = GND or VCC
0.13 0.55
0.55 V
II
IOFF
IPU/PD
IOZH
Input leakage current
Power-off leakage current
Power-up/down 3-State
output current4
3-State output High current
VCC = 5.5V; VI = GND or 5.5V
VCC = 0.0V; VO or VI ⤠4.5V
VCC = 2.1V; VO = 0.5V; VI = GND or VCC;
VOE = GND
VCC = 5.5V; VO = 2.7V; VI = VIL or VIH
±0.01 ±1.0
±5.0 ±100
±5.0 ±50
5.0 50
±1.0 µA
±100 µA
±50 µA
50
µA
IOZL
3-State output Low current VCC = 5.5V; VO = 0.5V; VI = VIL or VIH
IO
Output current1
VCC = 5.5V; VO = 2.5V
â5.0 â50
â50 µA
â50 â70 â180 â50 â180 mA
ICEX Output High leakage current VCC = 5.5V; VO = 5.5V; VI = GND or VCC
5.0 50
50
µA
ICCH
VCC = 5.5V; Outputs High, VI = GND or VCC
120 250
250 µA
ICCL Quiescent supply current
VCC = 5.5V; Outputs Low, VI = GND or VCC
44
60
60 mA
ICCZ
VCC = 5.5V; Outputs 3-State;
VI = GND or VCC
120 250
250 µA
âICC
Additional supply current per VCC = 5.5V; one input at 3.4V,
input pin2
other inputs at VCC or GND
0.5 1.5
1.5 mA
NOTES:
1. Not more than one output should be tested at a time, and the duration of the test should not exceed one second.
2. This is the increase in supply current for each input at 3.4V.
3. For valid test results, data must not be loaded into the flip-flops (or latches) after applying the power.
4. This parameter is valid for any VCC between 0V and 2.1V with a transition time of up to 10msec. From VCC = 2.1V to VCC = 5V ± 10% a
transition time of up to 100µsec is permitted.
August 23, 1993
4
|
▷ |