English
Language : 

BUK107-50DS Datasheet, PDF (3/9 Pages) NXP Semiconductors – PowerMOS transistor Logic level TOPFET
Philips Semiconductors
PowerMOS transistor
Logic level TOPFET
Product specification
BUK107-50DS
THERMAL CHARACTERISTICS
SYMBOL PARAMETER
Rth j-sp
Rth j-b
Rth j-a
Thermal resistance
Junction to solder point
Junction to board1
Junction to ambient
CONDITIONS
Mounted on any PCB
Mounted on PCB of fig. 19
MIN. TYP. MAX. UNIT
-
12 18 K/W
-
40
- K/W
-
-
70 K/W
STATIC CHARACTERISTICS
Tb = 25 ˚C unless otherwise specified
SYMBOL PARAMETER
V(CL)DSS
V(CL)DSS
Drain-source clamping voltage
Drain-source clamping voltage
IDSS
IDSS
IDSS
RDS(ON)
Off-state drain current
Off-state drain current
Off-state drain current
Drain-source on-state
resistance2
CONDITIONS
VIS = 0 V; ID = 10 mA
VIS = 0 V; IDM = 200 mA;
tp ≤ 300 µs; δ ≤ 0.01
VDS = 45 V; VIS = 0 V
VDS = 50 V; VIS = 0 V
VDS = 40 V; VIS = 0 V; Tj = 100 ˚C
II = 1.5 mA; IDM = 100 mA;
tp ≤ 300 µs; δ ≤ 0.01
MIN.
50
-
TYP.
55
56
MAX.
-
70
UNIT
V
V
-
0.5
2
µA
-
1
20 µA
-
10 100 µA
-
125 175 mΩ
INPUT CHARACTERISTICS
Tb = 25 ˚C unless otherwise specified. The supply for the logic and overload protection is taken from the input.
The input clamping is suitable for a drive circuit with a pull-up resistor.
SYMBOL PARAMETER
CONDITIONS
MIN. TYP. MAX. UNIT
VIS(TO)
IIS
IISL
VISR
V(CL)IS
RIG
Input threshold voltage
VDS = 5 V; ID = 1 mA
1.7 2.2 2.7 V
Input supply current
normal operation;
VIS = 6 V
-
550 750 µA
Input supply current
protection latched;
VIS = 5 V
-
500 650 µA
VIS = 3.5 V
-
250 400 µA
Protection latch reset voltage3
1
2.2 3.5
V
Input clamping voltage
Input series resistance
II = 1.5 mA
to gate of power MOSFET
6
7.5
-
V
-
33
-
kΩ
SWITCHING CHARACTERISTICS
Tamb = 25 ˚C; resistive load RL = 50 Ω; adjust VDD to obtain ID = 250 mA; refer to test circuit and waveforms
SYMBOL PARAMETER
CONDITIONS
MIN. TYP. MAX. UNIT
td on
Turn-on delay time
tr
Rise time
td off
Turn-off delay time
tf
Fall time
VIS = 0 V to II = 1.5 mA
II = 1.5 mA to VIS = 0 V
-
4
-
µs
-
16
-
µs
-
3
-
µs
-
6
-
µs
1 Temperature measured 1.3 mm from tab.
2 Continuous input voltage. The specified pulse width is for the drain current.
3 The input voltage below which the overload protection circuits will be reset.
March 1997
3
Rev 1.200