English
Language : 

PT7C4311 Datasheet, PDF (4/16 Pages) Pericom Semiconductor Corporation – Real-time Clock Module
PT7C4311
Real-time Clock Module (I2C Bus)
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
DC Electrical Characteristics
(Unless otherwise specified, VCC = 1.5 ~ 5.5 V, TA = -40 °C to +85 °C.)
Sym.
Description
Pin
Condition
Min Typ Max Unit
VCC
VBAT1
VSO2
Timing data and RAM data
maintaining voltage
Timing data writing voltage
Timing data reading voltage
RAM data writing voltage
RAM data reading voltage
Supply voltage
Battery Back-up Switchover
Voltage3,4
VCC -
VCC -
VCC -
VCC -
VCC
VBAT -
-
-
1.2
-
5.5
1.5
-
5.5
V
1.5
-
5.5
3.0
-
5.5
1.5
-
5.5
2.0
3
3.56
V
VBAT - VBAT - VBAT -
0.80 0.50 0.305
V
ICC Current consumption
IST Standby current
IBAT Current consumption
VIL Low-level input voltage
VIH High-level input voltage
Low-level output voltage
VOL Pull-up Supply voltage
(Open drain)
VCC
VCC
VBAT
-
Switch freq. = 400kHz
SDA, SCL = VCC – 0.3V
OSC on, VCC = 0V, VBAT = 3V,
TA=25°C
-
-
-
SDA
FT/
OUT
IOL = 3mA
-
-
70
150 A
-
25
80 A
-
300 800 nA
-0.3
-
0.3VCC
0.7VCC
-
VCC
V
+0.5
-
-
0.4
V
-
-
5.5
IIL Input leakage current
SCL
0<VIN<VCC
-
-
1 A
IOZ Output current when OFF
SDA
0<VOUT<VCC
-
-
1 A
Note:
1. After switchover (VSO), VBAT (min) can be 2.0V for crystal with RS=40k.
2. Switch-over and deselect point.
3. Valid for Ambient Operating Temperature: TA = -40 to 85°C; VCC = 2.0 to 5.5V (except where noted). VCC fall time should
not exceed 5 mV/μs.
4. All voltages referenced to GND.
5. In 3.3V application, if initial battery voltage is ≥ 3.4V, it may be necessary to reduce battery voltage (i.e., through wave
soldering the battery) in order to avoid inadvertent switchover/reselection for VCC – 10% operation.
6. For rechargeable backup, VBAT (max) may be considered to be VCC.
2015-06-0002
PT0322-8
06/16/15
4