English
Language : 

PT7M6709 Datasheet, PDF (2/12 Pages) Pericom Semiconductor Corporation – Multi-voltage Supervisor
PT7M6709/6714
Multi-voltage Supervisor
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Pin Description
Table 3 Pin description of PT7M6709
Pin
Name Type
Description
1
IN1
I
Input voltage 1
2
IN2
I
Input voltage 2
3
IN3
I
Input voltage 3
4
IN4
I
Input voltage 4
5
GND
P Ground
6
PWRGD4
O
Output 4. PWRGD4 asserts low when IN4 falls below its threshold voltage.
PWRGD4 is open drain with a 10μA internal pull-up current source to Vcc.
7
PWRGD3
O
Output 3. PWRGD3 asserts low when IN3 falls below its threshold voltage.
PWRGD3 is open drain with a 10μA internal pull-up current source to Vcc.
8
PWRGD2
O
Output 2. PWRGD2 asserts low when IN2 falls below its threshold voltage.
PWRGD2 is open drain with a 10μA internal pull-up current source to Vcc.
9
PWRGD1
O
Output 1. PWRGD1 asserts low when IN1 falls below its threshold voltage.
PWRGD1 is open drain with a 10μA internal pull-up current source to Vcc.
Supply Voltage. An undervoltage lockout circuit forces all PWRGD_outputs
10
VCC
P low when Vcc drops below the minimum operating voltage. Vcc is not a
monitored voltage.
Table 4 Pin description of PT7M6714
Pin Name Type
Description
1
MR
I Manual Reset Input. Force MR low to assert the RESET output. RESET remains asserted
for the reset timeout period after MR goes high. MR is internally pulled up to Vcc
Power-Fail Input 1. Input to noninverting input of the power-fail comparator. PFI1 is compared to
2
PFI1 I an internal 0.62V reference. Use an external resistor-divider network to adjust the monitor
threshold.
Power-Fail Input 2. Input to noninverting input of the power-fail comparator. PFI2 is compared to
3
PFI2 I an internal 0.62V reference. Use an external resistor-divider network to adjust the monitor
threshold.
Power-Fail Input 3. Input to noninverting input of the power-fail comparator. PFI3 is compared to
4
PFI3 I an internal 0.62V reference. Use an external resistor-divider network to adjust the monitor
threshold.
5
GND P Ground
6
PFO3 O Power-Fail output 3. PFO3 asserts low when PFI3 is below the selected threshold. PFO3 is an
active-low, open drain output with a 10μA internal pull-up to Vcc.
7
PFO2
O
Power-Fail output 2. PFO2 asserts low when PFI2 is below the selected threshold. PFO2 is an
active-low, open drain output with a 10μA internal pull-up to Vcc.
8
PFO1
O
Power-Fail output 1. PFO1 asserts low when PFI1 is below the selected threshold. PFO1 is an
active-low, open drain output with a 10μA internal pull-up to Vcc.
9
RESET
O
Reset output. RESET is an active-low, open-drain output that asserts low when Vcc drops
below its preset threshold voltage or when a manual reset is initiated. RESET remains
low for the reset timeout period after Vcc exceeds the selected reset threshold or MR is released.
10
VCC P Supply Voltage. RESET asserts low when Vcc drops below its threshold.
12-07-0002
PT0235-2
07/05/12
2