English
Language : 

PT7M6314US Datasheet, PDF (2/8 Pages) Pericom Semiconductor Corporation – Supervisory Circuit
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
PT7M6314US
Supervisory Circuit
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Maximum Ratings
Storage Temperature ............................................................-65C to +150C
Ambient Temperature with Power Applied .......................... -40C to +85C
Supply Voltage to Ground Potential (Vcc to GND) ..............-0.3V to +7.0V
DC Input Voltage (All inputs except Vcc and GND)......-0.3V to VCC+0.3V
DC Output Current (All outputs) ..........................................................30mA
Power Dissipation .......................................... 320mW (Depend on package)
DC Electrical Characteristics
Note:
Stresses greater than those listed under MAXIMUM
RATINGS may cause permanent damage to the
device. This is a stress rating only and functional
operation of the device at these or any other condi-
tions above those indicated in the operational sec-
tions of this specification is not implied. Exposure
to absolute maximum rating conditions for extended
periods may affect reliability.
(TA= -40~85ºC, unless otherwise noted. Typical values are at TA = +25ºC)
Description
Sym.
Test Conditions
Supply Voltage
Supply Current
VCC
VCC = 5.5V. No load.
ICC
VCC = 3.6V. No load.
Voltage Threshold
+25C
VTH-
-40C~85C
Hysteresis
VHYS
VTH+ - VTH-*
Output
Driving
Output low
IOH = 8mA, VCC = 5V
VOL IOH = 4mA, VCC = 3V
IOH = -50µA, VCC = 1V
MR
Min.
1.0
(VTH-)
0.985
(VTH-)
0.975
32
Typ.
VTH-
VTH-
50
63
Max. Unit
5.5
V
12
µA
10
µA
(VTH-)
1.015
V
(VTH-)
1.025
mV
0.4
0.3
V
0.09
100 k
Internal pull-up resistor
RP
RST pin. VCC = 3V.
RST pin. VCC = 5V.
-
11
20
k
-
5
10
Input High Voltage
Input Low Voltage
RST active pull-up enable
threshold
VIH
VIL
VTHUP
VCC < 4V
MR
VCC > 4V
VCC < 4V
MR
VCC > 4V
VCC = 5V
0.7×Vcc
2.4
V
0.3×Vcc
V
0.8
0.7
0.9
1.2
V
RST active pull-up current
VCC = 3.3V
20
mA
Note: VTH- is voltage threshold when VCC falls from high to low. VTH+ is voltage threshold when VCC rises from low to high.
2016-01-0003
PT0196-6
01/15/16
2