English
Language : 

PI2PCIE412-D Datasheet, PDF (2/9 Pages) Pericom Semiconductor Corporation – Enhanced, 1.8V, PCI Express Compliant, 4-Differential Channel, 2:1 Mux/DeMux Switch, w/ Single Enable
PI2PCIE412-D
Enhanced, 1.8V, PCI Express Compliant,
4-Differential Channel, 2:1 Mux/DeMux Switch
Maximum Ratings
(Above which useful life may be impaired. For user guidelines, not tested.)
Storage Temperature ....................................................–65°C to +150°C
Supply Voltage to Ground Potential ................................–0.5V to +2.5V
DC Input Voltage ...............................................................–0.5V to VCC
DC Output Current ....................................................................... 120mA
Power Dissipation ........................................................................... 0.5W
Note: Stresses greater than those listed under MAXIMUM
RATINGS may cause permanent damage to the device. This
is a stress rating only and functional operation of the device
at these or any other conditions above those indicated in the
operational sections of this specification is not implied. Expo-
sure to absolute maximum rating conditions for extended
periods may affect reliability.
DC Electrical Characteristics for Switching over Operating Range (TA = –40°C to +85°C, VCC = 1.5V to 2.0V)
Paramenter
Description
Test Conditions(1)
Min
Typ(2)
Max Units
VIH
Input HIGH Voltage
Guaranteed HIGH level
0.65 x VCC
VIL
Input LOW Voltage
Guaranteed LOW level
–0.5
0.35 x VCC V
VIK
Clamp Diode Voltage
VCC = Max., IIN = –18mA
–0.7
–1.2
IIH
Input HIGH Current
VCC = Max., VIN = VCC
IIL
Input LOW Current
VCC = Max., VIN = GND
±5
µA
±5
Power Supply Characteristics
Parameters
Description
ICC
Quiescent Power Supply Current
Test Conditions(1)
VCC = Max., VIN = GND or VCC
Min.
Typ.(2)
200
Max.
Units
µA
Dynamic Electrical Characteristics Over the Operating Range (TA= -40º to +85ºC, VCC = 1.8V±10%, GND=0V)
Parameter
Description
Test Conditions
Min. Typ.(2) Max. Units
XTALK
Crosstalk
See Fig. 1 for Measurement Setup, f = 10 MHz
-65
dB
OIRR
OFF Isolation
See Fig. 2 for Measurement Setup, f = 10 MHz
-65
Notes:
1. For Max. or Min. conditions, use appropriate value specified under Electrical Characteristics for the applicable device type.
2. Typical values are at VCC = 1.8V, TA = 25°C ambient and maximum loading.
2
PS8788B
01/23/06