PI3EQX6741ST Datasheet, PDF (1/9 Pages) Pericom Semiconductor Corporation – 3.3V, 1-port, SATA Gen 3i ReDriver with Adjustable Equalization/Pre-Emphasis | |||
|
PI3EQX6741ST
3.3V, 1-port, SATA Gen 3i ReDriver⢠with
Adjustable Equalization/Pre-Emphasis
Features
ÃÃSupports SATA Gen 3i.
ÃÃTwo 6Gbps differential signal pairs
ÃÃ100⦠Differential CML I/Oâs
ÃÃInput signal level detect and squelch for each channel
ÃÃOOB Support
ÃÃAutomatic HDD Rate detection for output swing/emphasis
setting
ÃÃTermination detect indication
à à Power saving mode control to Host or HDD
ÃÃAdjustable Receiver Equalization
ÃÃSelectable Output Pre-emphasis and Swing Control
ÃÃHigh impedance I/O termination in standby mode
ÃÃESD +/-8kV
ÃÃLow Power Operation: 254mW typical
ÃÃAuto-Slumber Mode: 36mW typical
ÃÃHDD unplugged: 3.6mW
ÃÃPower down Stand-by Mode: 0.7mW max
ÃÃSupply Voltage: 3.3V ±10%
ÃÃIndustrial Temperature Range: -40oC to 85oC
ÃÃPackaging: 20-TQFN (4x4mm)
Description
Pericomâs PI3EQX6741ST is a low power, signal SATA Gen
3i 6Gbps ReDriverâ¢. The device provides programmable equal-
ization and output emphasis, to optimize performance over a
variety of physical mediums by reducing Inter-Symbol Interfer-
ence. PI3EQX6741ST supports two 100⦠Differential CML data
I/Oâs between the Protocol ASIC to a switch fabric, across a back-
plane, or to extend the signals across other distant data pathways
on the userâs platform.
The integrated equalization circuitry provides flexibilitywith
signal integrity of the signal before the ReDriver.
A low-level input signal detection and output squelch function
is provided for each channel. Each channel operates fully inde-
pendently. When the channels are enabled (EN=1) and operating,
that channels input signal level (on xI+/-) determines whether the
output is active. If the input signal level of the channel falls below
the active threshold level (Vth-) then the outputs are driven to the
common mode voltage.
Termination Detect indication (TDet_A# or TDET_B#) provides
indication when the load is connected ie HDD or Host. This can
be used as control to go into power saving mode by either the host
or HDD.
In addition to signal conditioning, when EN = 0, the device
enters a low power standby mode.
Applications
ÃÃNotebook, desktop, docking station, Set Top Box, Server
Workstation, Data Storage
Pin Diagram (Top Side View)
AI+
AI-
TDet_B#
BO-
BO+
20 19 18 17 16
1
15
2
14
3
GND 13
4
12
5
11
6 7 8 9 10
AO+
AO-
TDet_A#
BI-
BI+
Block Diagram
Signal Detection
CML
50â¦
xl+
xl-
VBIAS = 1.05V
50â¦
Equalizer
Limiting
Amp
- Repeated 2 times -
TDet#
CML
xO+
xO-
Power
Control
EN
Management
Circuit
TDet_EN
x_EQ
x_EM
All trademarks are property of their respective owners.
16-0050