English
Language : 

PI3EQX6741ST Datasheet, PDF (1/9 Pages) Pericom Semiconductor Corporation – 3.3V, 1-port, SATA Gen 3i ReDriver with Adjustable Equalization/Pre-Emphasis
PI3EQX6741ST
3.3V, 1-port, SATA Gen 3i ReDriver™ with
Adjustable Equalization/Pre-Emphasis
Features
ÎÎSupports SATA Gen 3i.
ÎÎTwo 6Gbps differential signal pairs
ÎÎ100Ω Differential CML I/O’s
ÎÎInput signal level detect and squelch for each channel
ÎÎOOB Support
ÎÎAutomatic HDD Rate detection for output swing/emphasis
setting
ÎÎTermination detect indication
àà Power saving mode control to Host or HDD
ÎÎAdjustable Receiver Equalization
ÎÎSelectable Output Pre-emphasis and Swing Control
ÎÎHigh impedance I/O termination in standby mode
ÎÎESD +/-8kV
ÎÎLow Power Operation: 254mW typical
ÎÎAuto-Slumber Mode: 36mW typical
ÎÎHDD unplugged: 3.6mW
ÎÎPower down Stand-by Mode: 0.7mW max
ÎÎSupply Voltage: 3.3V ±10%
ÎÎIndustrial Temperature Range: -40oC to 85oC
ÎÎPackaging: 20-TQFN (4x4mm)
Description
Pericom’s PI3EQX6741ST is a low power, signal SATA Gen
3i 6Gbps ReDriver™. The device provides programmable equal-
ization and output emphasis, to optimize performance over a
variety of physical mediums by reducing Inter-Symbol Interfer-
ence. PI3EQX6741ST supports two 100Ω Differential CML data
I/O’s between the Protocol ASIC to a switch fabric, across a back-
plane, or to extend the signals across other distant data pathways
on the user’s platform.
The integrated equalization circuitry provides flexibilitywith
signal integrity of the signal before the ReDriver.
A low-level input signal detection and output squelch function
is provided for each channel. Each channel operates fully inde-
pendently. When the channels are enabled (EN=1) and operating,
that channels input signal level (on xI+/-) determines whether the
output is active. If the input signal level of the channel falls below
the active threshold level (Vth-) then the outputs are driven to the
common mode voltage.
Termination Detect indication (TDet_A# or TDET_B#) provides
indication when the load is connected ie HDD or Host. This can
be used as control to go into power saving mode by either the host
or HDD.
In addition to signal conditioning, when EN = 0, the device
enters a low power standby mode.
Applications
ÎÎNotebook, desktop, docking station, Set Top Box, Server
Workstation, Data Storage
Pin Diagram (Top Side View)
AI+
AI-
TDet_B#
BO-
BO+
20 19 18 17 16
1
15
2
14
3
GND 13
4
12
5
11
6 7 8 9 10
AO+
AO-
TDet_A#
BI-
BI+
Block Diagram
Signal Detection
CML
50Ω
xl+
xl-
VBIAS = 1.05V
50Ω
Equalizer
Limiting
Amp
- Repeated 2 times -
TDet#
CML
xO+
xO-
Power
Control
EN
Management
Circuit
TDet_EN
x_EQ
x_EM
All trademarks are property of their respective owners.
16-0050
1